18- ENG
Westward Operating Instructions and Parts Manual
Model 4YD76A
Portable Air Compressor
Symptom (s)
Possible Causes (s)
Corrective Actions (s)
Motor will not
run.
1a. Check fuse box for blown
fuse and replace as
necessary. Reset
circuit breaker. Do not
use a fuse or circuit
breaker with higher
rating than that specified
for your particular branch
circuit.
b.
Check for proper fuse.
You should use a time
delay fuse.
c.
Check for low voltage
problem.
d.
Check the extension
cord.
e.
Disconnect the other
electrical appliances from
circuit or operate the
compressor on its own
branch circuit.
4.
Have checked by a
trained service
technician.
1.
Fuse blown, circuit
breaker tripped.
2.
Extension cord is wrong
length or gauge.
3.
Loose electrical
connections.
4.
Faulty motor.
2.
Check the extension
cord.
3.
Check wiring connection
inside terminal box.