10- ENG
Westward Operating Instructions and Parts Manual
Model 4YD76A
Portable Air Compressor
EXTENSION CORDS
Use extra air hose instead of an
extension cord to avoid voltage drop
and power loss to the motor, and to
prevent overheating.
If an extension cord must be used, be
sure it is:
•
a 3-wire extension cord that has
a 3-blade grounding plug, and a
3-slot receptacle that will accept
the plug on the product
•
in good condition
•
no longer than 50 feet
•
12 gauge (AWG) or larger. (Wire
size increases as gauge number
decreases. 10 AWG and 8 AWG
may also be used. DO NOT USE
14 OR 16 AWG.)
VOLTAGE AND CIRCUIT
PROTECTION
Refer to the specifications for the
voltage and minimum branch circuit
requirements.
Certain air compressors can be
operated on a 15 amp circuit if the
following conditions are met.
1.
Voltage supply through branch
circuit is 15 amps.
2.
Circuit is not used to supply any
other electrical needs (lights,
appliances, etc.).
3.
Extension cords comply with
specifications.
4.
Circuit is equipped with a 15 amp
circuit breaker or 15 amp time
delay fuse.
NOTE:
If compressor
is connected to a circuit protected
by fuses, use only time delay
fuses. Time delay fuses should
be marked “D” in Canada and “T”
in the US.
If any of the above conditions cannot
be met, or if operation of the
compressor repeatedly causes
interruption of the power, it may be
necessary to operate it from a 20 amp
circuit. It is not necessary to change
the cord set.