background image

 
 
 
 

  

 
 
 

 

22YM05

Westward Operating Instructions Manual 

Battery Load Tester

 

 
 
IMPORTANT:

 Make sure that the RED or POSITIVE 

clamp does not touch any other part of the vehicle, 
and be particularly careful where you place the tester 
inside the engine compartment. The main body of the 
tester is metal, and if placed carelessly, it could cause 
a short circuit and damage the electrical system. 

 
NOTE:

  Avoid dropping the battery tester as this could 

cause damage, which may prevent it from working. 

 
Operation 

 

BATTERY TEST

  

 

1.  Connect the RED clamp to the POSITIVE 

terminal, and the BLACK clamp to the 
NEGATIVE terminal, make sure the contacts are 
clean and firm, and that on small batteries, there 
is absolutely no possibility of the clamps touching 
each other. 
 

2. 

Push the load switch and hold for at least 10 
seconds to allow the load to take effect. With the 
load switch held, read the condition of the battery 
on the scale provided, referring to the Battery 
Analysis chart on the back cover of these 
instructions and/or on the battery tester. 

 

 
 
CHARGING SYSTEM TEST 

 
Connect the leads to the battery (as mentioned under 
part 1 of “BATTERY TEST” Operation), and run the 
engine at a fast idle speed. Read the gauge (charging 
system). DO NOT OPERATE THE LOAD SWITCH. 

 

 
Maintenance 

 

OPERATION

  

 

With the meter disconnected from the battery, make 
sure the gauge needle is set to zero, using the screw 
on the front of the gauge as necessary. 
 
As the metal clamps are liable to come into contact 
with battery electrolyte, it is advisable to wipe them 
clean and dry after use, and apply a thin film of silicon 
grease to prevent the possibility of corrosion. 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 22YM05

Page 1: ...for any damage that may have occurred during transit Check for loose missing or damaged parts Shipping damage claim must be filed with carrier With the meter disconnected from the battery make sure the gauge needle is set to zero using the screw on the front of the gauge as necessary Specifications and Dimensions Model Battery Type Load Range Dimensions Inches Weight Length Width Height Lbs 22YM05...

Page 2: ...y of the clamps touching each other 2 Push the load switch and hold for at least 10 seconds to allow the load to take effect With the load switch held read the condition of the battery on the scale provided referring to the Battery Analysis chart on the back cover of these instructions and or on the battery tester CHARGING SYSTEM TEST Connect the leads to the battery as mentioned under part 1 of B...

Page 3: ...bring SG to full charge level then battery is either sulfated or has lost its active material Weak or Bad needle failing Battery may be defective i e a bad cell For a quick check release load switch and note volt meter reaction If voltage recovers to its full potential after only a few seconds the battery is probably defective If the voltage recovers slowly the battery may only be very run down Fo...

Page 4: ...auciones de seguridad Esto asegura su propia seguridad y la de los que le rodean Desembalaje Después de desempacar la unidad inspeccione cuidadosamente por cualquier daño que pueda haber ocurrido durante el transporte Compruebe partes perdidas dañadas o sueltas Reclamación de daños ha de presentarse con el portador Con el medidor desconectado de la batería asegúrese de que la aguja del indicador s...

Page 5: ... NEGATIVO asegúrese de que los contactos están limpios y firmes y que en las baterías pequeñas no hay absolutamente ninguna posibilidad de que las pinzas se tocan 2 Empuje el interruptor de carga y mantenga durante al menos 10 segundos para permitir que la carga tenga efecto Con el interruptor de carga realizada lea el estado de la batería en la escala provista en referencia a la tabla de Análisis...

Page 6: ...lares Si la carga no trae SG de nivel de carga completa entonces la batería está bien sulfatada o ha perdido su material activo Débil o Malo aguja de defecto La batería puede estar defectuosa es decir una mala célula Para verificar rápidamente suelte el interruptor de carga y note la reacción de voltímetro Si la tensión se recupera todo su potencial después de sólo unos pocos segundos la batería e...

Page 7: ...elle des votre entourage Déballage Après avoir déballé l appareil inspectez soigneusement tous les dégâts qui se produisent pendant le transport Vérifiez les pièces détachées manquantes ou endommagées la réclamation de dommages dûs à l expédition doit être déposée auprès transporteur Avec l appareil de mesure déconnecté de la batterie Vous assurez que l aiguille de l indicateur soit mis à zéro uti...

Page 8: ...tacts soient propres et fermés et que pour les petites batteries il n y a absolument aucune possibilité pour les pinces se touchent 2 Appuyez sur l interrupteur de charge et maintenez pendant au moins 10 secondes pour permettre à la charge de prendre l effet Avec le commutateur de charge tenue lire l état de la batterie sur l échelle fournie se référant à la grille d analyse de la batterie sur le ...

Page 9: ...pporte pas de DS à niveau de pleine charge puis la batterie est sulfatés ou bien elle a perdu son matériel actif Faible ou Mauvais aiguille à défaut La batterie peut être défectueuse c est à dire une mauvaise cellule Pour une vérification rapide relâchez le commutateur de charge et notez la réaction de voltmètre Si la tension se rétablit à son plein potentiel au bout de quelques secondes la batter...

Reviews: