Westlab 665-090 Product Manual Download Page 8

8

PRODUCT MANUAL

1800 358 101

[email protected]

www.westlab.com.au

+64 9 553 3677

[email protected]

www.westlab.co.nz

646 568 5391

[email protected]

www.westlab.com

1 877 822 1455

[email protected]

www.westlab.com

Australia

New Zealand

United States

Canada

Setting the time

1.  Press the ‘Time’ button to select the time value
2.  Press the ‘Increment/Decrement’ button to set the run time

The run time for operation can be set between one minute to 99 minutes with 

incremental or decremental steps of one minute. The time can also be set for 

continuous or infinite mode indicated by ‘][’ in the time display. The time values are 

saved after blinking five times.

The countdown timer will be activated as soon as the operation begins. The time 

setting cannot be modified when the unit is in operation.

Operating the Start/Stop button

1.  Once the required speed and time values are set, press the ‘Start/Stop’ button to 

start the operation. The speed will gradually increase from a lower RPM to the set 

RPM and time value.

2.  Press the ‘Start/Stop’ button again to stop the ongoing operation. The speed will 

gradually decrease from the set RPM to zero.

ATTENTION: The speed and time values cannot be changed or modified during operation.

Default pulse mode

The pulse mode is used for vigorous mixing of samples by rolling with a momentary 

pause every 30 seconds. The default cycle time set for pulse mode is 30 seconds.

1.  Press the ‘Start/Stop’ button again to stop the ongoing operation at any time.  

The speed will gradually decrease from the set RPM to zero.

2.  Set required speed and total run time before activating the pulse mode to guide the 

device to start pulse mode operation for that particular speed and total run time.

3.  Once the speed and total run time are set, press the ‘Pulse’ button to start pulse 

mode operation for that particular speed and total run time.

4.  In pulse mode, the pulse LED will glow indicating pulse mode opera¬tion is activated. 

 

Example: Speed set to 50 RPM and total run time set to 2 min¬utes. Pulse mode 

operation will have a speed of 50 RPM and total run time of 2 minutes. There will 

be rolling for 30 seconds (cycle time) with momentary pause in-between and then 

rolling for 30 seconds (cycle time) for a total of 2 minutes (total run-time).

5.  Press the ‘Pulse’ button again to stop ongoing pulse mode operation. The user can 

also press the ‘Start/Stop’ button to stop the ongoing pulse mode operation.

Programmable pulse mode

The user can also program the pulse mode and set it for alternating timers for  

30 seconds to 90 seconds.

1.   Set the required speed and total run time for operation
2.   Hold down the ‘Pulse’ button to select the cycle time of rolling. The cycle time 

value will appear on the right side of the display. ‘SEC’ will appear on the left side of 

the display and the pulse LED will begin blinking indicating that the user can now 

modify the cycle time.

Summary of Contents for 665-090

Page 1: ...1 PRODUCT MANUAL Product Manual Roller 6 Tubes 80RPM Max Code 665 090...

Page 2: ...d suspensions 1 3 Features Gentle rocking and rolling system for optimal mixing Adjustable speed ranging from 10 to 80 RPM Timer ranging from 1 minute to 99 mins and infinite mode Maintenance free bru...

Page 3: ...Specification Motor Type Brushless DC motor Number of Tube Rollers 6 Rollers Rocking Motion Rolling and rocking Speed Range 10 to 80 RPM Speed Accuracy 5 RPM Speed Steps 1 RPM Tilt Angle 3 Timer Range...

Page 4: ...o mix explosive or highly reactive substances Do not place the potential hazardous material within the clearance area or envelope Wear your personal protective equipment in accordance with the hazards...

Page 5: ...our feet stand on the surface firmly Avoid installing on a slippery surface or surface prone to vibration 2 Ideal ambient temperature is 20 C 5 C avoid placing the device in direct sunlight 3 Keep the...

Page 6: ...com www westlab com 1 877 822 1455 sales ca westlab com www westlab com Australia New Zealand United States Canada Installing the rollers Follow the exact reverse process to insert the roller back to...

Page 7: ...rt Stop Press the Start Stop button to start the operation or to stop the ongoing operation 7 Pulse and LED Press the Pulse button once to start the pulse operation and press it again to stop the oper...

Page 8: ...ery 30 seconds The default cycle time set for pulse mode is 30 seconds 1 Press the Start Stop button again to stop the ongoing operation at any time The speed will gradually decrease from the set RPM...

Page 9: ...t Stop button to stop the ongoing pulse mode operation Program mode The program mode feature allows the user to save up to nine programs with different speed and time parameters Users can use any of t...

Page 10: ...ved Press the Start button to start the program mode operation Once the set RPM is reached the program Px with x 1 to 9 and its Speed and Time values will display alternatively 7 To stop the operation...

Page 11: ...eed time and other values set by the user When the power restarts the roller will run for the remaining time left with a cycle time of 5 minutes The unit will save the run time every five minutes of o...

Page 12: ...Westlab in every discovery 12 PRODUCT MANUAL...

Reviews: