3. Safety Precautions

• 

Never use the instrument in any manner not specified in this manual.

• 

Equipment used in any manner not specified in this manual or by the manufacturer might 

result in the lapse of warranty.

• 

Do not try to stop the roller by blocking or holding it. Do not attempt to remove rollers 

during operation.

• 

Never move the instrument while the equipment is under operation.

• 

Repairs must only be performed by authorised service technician.

• 

Only use recommended original spare parts for best result and product safety.

• 

If liquids are spilled on the roller, the instrument must be cleaned carefully and properly 

before being used again.

• 

Prior to mixing, the tubes should be visually inspected for material damage. Damaged 

tubes must not be used as this can result in sample loss and the contamination of  

the product.

• 

The maximum capacity of 2kg must not be exceeded.

• 

This product must be used for specified applications only. It must not be operated in a 

hazardous or flammable environment and must not be used to mix explosive or highly 

reactive substances.

• 

Do not place the potential hazardous material within the clearance area or envelope.

• 

Wear your personal protective equipment in accordance with the hazards category of the 

medium to be processed. There is risk of liquid splashing.

• 

Place the instrument on a flat, levelled, and solid surface. Make sure the feet of the 

instrument are clean and undam¬aged.

• 

Load the tubes safely between the rollers. Always distribute the samples evenly on the device.

• 

Do not move the instrument while it is operating or con¬nected to the main power supply.

• 

Ensure that the hinges are properly locked before perform¬ing any operation.

• 

Do not apply any pressure to the hinges. They should be used only for locking and 

unlocking rollers.

• 

Remove the roller/s one after another.

• 

Ensure that only closed tubes are used for mixing and rolling.

• 

Do not lean on the equipment. It may damage the equipment or harm the operator.

• 

Do not fill tubes near the device. Liquid spillage may harm the device.

• 

In the event of contamination caused by aggressive agents, the device must be cleaned 

immediately using a natural cleaning liquid. If any damage is seen, contact the service 

technician.

• 

The power adaptor given with the unit is designed to be used for this unit. Do not use any 

other power adaptor.

• 

Only process media which will not react dangerously to the extra energy produced by mixing.

• 

Do not operate the appliance in explosive atmosphere with hazardous substance or  

under water.

Summary of Contents for 665-090

Page 1: ...1 PRODUCT MANUAL Product Manual Roller 6 Tubes 80RPM Max Code 665 090...

Page 2: ...d suspensions 1 3 Features Gentle rocking and rolling system for optimal mixing Adjustable speed ranging from 10 to 80 RPM Timer ranging from 1 minute to 99 mins and infinite mode Maintenance free bru...

Page 3: ...Specification Motor Type Brushless DC motor Number of Tube Rollers 6 Rollers Rocking Motion Rolling and rocking Speed Range 10 to 80 RPM Speed Accuracy 5 RPM Speed Steps 1 RPM Tilt Angle 3 Timer Range...

Page 4: ...o mix explosive or highly reactive substances Do not place the potential hazardous material within the clearance area or envelope Wear your personal protective equipment in accordance with the hazards...

Page 5: ...our feet stand on the surface firmly Avoid installing on a slippery surface or surface prone to vibration 2 Ideal ambient temperature is 20 C 5 C avoid placing the device in direct sunlight 3 Keep the...

Page 6: ...com www westlab com 1 877 822 1455 sales ca westlab com www westlab com Australia New Zealand United States Canada Installing the rollers Follow the exact reverse process to insert the roller back to...

Page 7: ...rt Stop Press the Start Stop button to start the operation or to stop the ongoing operation 7 Pulse and LED Press the Pulse button once to start the pulse operation and press it again to stop the oper...

Page 8: ...ery 30 seconds The default cycle time set for pulse mode is 30 seconds 1 Press the Start Stop button again to stop the ongoing operation at any time The speed will gradually decrease from the set RPM...

Page 9: ...t Stop button to stop the ongoing pulse mode operation Program mode The program mode feature allows the user to save up to nine programs with different speed and time parameters Users can use any of t...

Page 10: ...ved Press the Start button to start the program mode operation Once the set RPM is reached the program Px with x 1 to 9 and its Speed and Time values will display alternatively 7 To stop the operation...

Page 11: ...eed time and other values set by the user When the power restarts the roller will run for the remaining time left with a cycle time of 5 minutes The unit will save the run time every five minutes of o...

Page 12: ...Westlab in every discovery 12 PRODUCT MANUAL...

Reviews: