background image

22 | Westinghouse Outdoor Power Equipment, LLC

 

BATTERY MAINTENANCE

The 12V 1.2 AH Lithium Ion battery shipped with the 

generator has been fully charged. A battery may lose some 

charge when not in use for prolonged periods of time.  

Note: 

Once started, the generator will charge the battery 

after 30 minutes of use.  

BATTERY REPLACEMENT

Keep battery terminals covered at all times. The 

generator is shipped with a lithium ion (Li-Ion) battery. 

Exposed metal positive and negative terminals can 

short-circuit when they come into contact with metal 

objects, igniting the cell’s internal materials and forcibly 

expelling burning contents, resulting in fires, explosions, 

serious injuries and even death.

1. 

Loosen and remove the bolts securing the battery hold-

down plate and remove the plate. 

2. 

Disconnect the quick-connect plugs and remove the 

battery from the unit. 

3. 

Disconnect the quick-disconnect cable leads from the 

battery. 

4. 

On the replacement battery, connect the white (-) quick-

connect cable to the battery negative terminal. Slide the 

rubber boot over the connection hardware. 

5. 

Connect the red (+) quick-connect cable to the battery 

positive terminal. Slide the rubber boot over the 

connection hardware. 

6. 

Install the battery into the generator. Reinstall the battery 

hold-down plate and tighten the bolts. 

7. 

Connect the quick-connect plug. 

NOTICE

Dispose of the used battery properly according to the 

guidelines established by your local or state government.

STORAGE

Proper storage preparation is required for trouble-free 

operation and generator longevity.  

NOTICE

Gasoline stored for as little as 30 days can deteriorate, 

causing gum, varnish, and corrosive buildup in fuel lines, 

fuel passages, and the engine. This corrosive buildup 

restricts the flow of fuel, which can prevent the engine 

from starting after a prolonged storage period. The use 

of fuel stabilizer significantly increases the storage life of 

gasoline. Full-time use of fuel stabilizer is recommended. 

Follow the manufacturer’s instructions for use. 

STORAGE TIME

RECOMMENDED PROCEDURE

Less than 1 month

No service required.

2 to 6 months

Fill with fresh gasoline and add 

gasoline stabilizer. Drain the 

carburetor float bowl.

6 months or longer

Drain the fuel tank and carburetor 

float bowl. 

SHORT TERM STORAGE

•  Allow the generator to cool a minimum of 30 minutes 

before storage.  

•  Replace all protective covers on the generator control 

panel. 

•  Wipe the generator with a moist cloth. Clean any debris 

from the muffler cooling vents.   

•  Store the generator in a well-ventilated, dry location 

away from sparks, open flames, pilot lights, heat, and 

other sources of ignition such as areas with a spark-

producing electric motor or where power tools are 

operated. 

• 

DO NOT

 store the generator, or gasoline near furnaces, 

water heaters, or any other appliances that produce 

heat or have automatic ignitions.

•  With the engine and exhaust system cool and all 

surfaces dry, cover the generator to keep out dust. 

DO 

NOT

 use a plastic sheet as a dust cover. Non-porous 

materials trap moisture and promote rust and corrosion. 

LONG TERM STORAGE

Even properly stabilized fuel can leave residue and cause 

corrosion if left long term. If storing the generator for two to 

six months, drain the float bowl to prevent gum and varnish 

buildup in the carburetor. 

MAINTENANCE

Summary of Contents for WGen5300sc

Page 1: ...ANUAL DO NOT RETURN THIS PRODUCT TO THE STORE If you have questions or need assistance please call customer service at 855 944 3571 WGen5300sc Portable Generator Gasoline 5300 Running Watts 6600 Peak...

Page 2: ...result in serious injury or death SAVE THESE INSTRUCTIONS TABLE OF CONTENTS INTRODUCTION DISCLAIMERS 2 ALL RIGHTS RESERVED 2 SPECIFICATIONS 3 SAFETY SAFETY DEFINITIONS 4 SAFETY SYMBOLS 4 SAFETY INSTR...

Page 3: ...emperatures up to 104 F 40 C If needed this product can be operated at temperatures ranging from 5 F 15 C 122 F 50 C for short periods If the product is exposed to temperatures outside of this range d...

Page 4: ...uld result in death or serious injury Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can cause damage to the generator...

Page 5: ...codes Electrocution hazard NEVER use the generator in a location that is wet or damp NEVER expose the generator to rain snow water spray or standing water while in use Protect the generator from all h...

Page 6: ...he generator NEVER remove the fuel cap when the generator is running Shut off the engine and allow the unit to cool at least two minutes Remove the fuel cap slowly to release pressure keep fuel from e...

Page 7: ...Westinghouse Outdoor Power Equipment LLC 7 SAFETY LABELS SAFETY...

Page 8: ...l battery powered carbon monoxide alarm s in your home Automatic shutoff accompanied with a flashing RED light in the CO Sensor portion of the control panel is an indication that the generator was imp...

Page 9: ...eptacles Receptacles can supply a maximum of 20 Amps 8 20 Amp AC Circuit Breaker Circuit breaker limits the current that can be delivered through the NEMA 5 20R receptacles to 20 Amps 9 30 Amp AC Circ...

Page 10: ...R COMPONENTS Oil drain bolt Oil dipstick filler neck Fuel cap Fuel gauge Muffler spark arrestor Carbon canister Carburetor Alternator cover Control panel Recoil Starter Air filter Fuel tank valve Spar...

Page 11: ...components Item Quantity Mounting foot 2 Flange bolt M8 4 Wheel 2 Axle pin 2 Washer 2 Cotter pin 2 If any parts are missing contact our service team at service wpowereq com or call 1 855 944 3571 INST...

Page 12: ...fuel screen filter Overfilling may cause fuel to spill onto engine causing a fire or explosion hazard Fire and explosion hazard NEVER refuel the generator while the engine is running ALWAYS turn the e...

Page 13: ...e red maximum fill ring on the fuel screen filter visible in the filler neck 5 Install the fuel cap NOTICE Fuel can damage paint and plastic Use caution when filling the fuel tank Damage caused by spi...

Page 14: ...l ventilated area DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces Carefully consider wind and air currents when positioning the gen...

Page 15: ...fuel selector switch on the control panel to gasoline operation 4 Turn the fuel tank valve to the ON position Note If cold starting move the choke lever to the ON position 5 Choose the starting metho...

Page 16: ...er ON GENERATOR CAPACITY NOTICE DO NOT overload the generator s capacity Exceeding the generator s wattage amperage capacity can damage the generator and or electrical devices connected to it Make sur...

Page 17: ...N CORDS Asphyxiation hazard Extension cords running directly into the home increase the risk of carbon monoxide poisoning through any openings If an extension cord running directly into your home is u...

Page 18: ...frame to lift the unit or attach any load restraints such as ropes or tie down straps DO NOT attempt to lift or secure the generator by holding onto any of its other components Keep the unit level dur...

Page 19: ...formed by authorized Westinghouse service dealer MAINTENANCE REMINDERS Maintenance reminder codes will be shown on the Data Display based on unit Lifetime Hours The maintenance codes will be displayed...

Page 20: ...tally and recheck until the level is between the L and H marks on the dipstick DO NOT overfill If over the H mark on the dipstick drain the oil to reduce the oil level to the full mark 6 Replace the o...

Page 21: ...park plug wrench 8 Attach the spark plug boot SPARK ARRESTOR SERVICE Allow the muffler to cool completely before servicing the spark arrestor Check and clean the spark arrestor after every 100 hours o...

Page 22: ...evity NOTICE Gasoline stored for as little as 30 days can deteriorate causing gum varnish and corrosive buildup in fuel lines fuel passages and the engine This corrosive buildup restricts the flow of...

Page 23: ...Storing the engine in this position will help prevent internal corrosion Return the recoil handle gently 8 Reinstall the spark plug Leave the spark plug boot disconnected to prevent accidental startin...

Page 24: ...occurred Relocate generator Contact Westinghouse customer service toll free at 1 855 944 3571 Engine starts then shuts down Out of fuel Refuel Incorrect engine oil level Check engine oil level Dirty...

Page 25: ...Westinghouse Outdoor Power Equipment LLC 25 EXPLODED VIEWS AND PARTS LISTS ENGINE EXPLODED VIEW EXPLODED VIEWS...

Page 26: ...R HEAD COVER ASSEMBLY 9 1 91329 BOLT 9 2 96225 CYLINDER HEAD COVER GASKET NO PART DESCRIPTION 9 3 401102 CYLINDER HEAD INTERNAL COVER 9 4 96226 INTERNAL COVER GASKET 9 5 401101 CYLINDER HEAD COVER 9 6...

Page 27: ...OIL STARTER ASSEMBLY 16 1 91325 BOLT 16 2 404707 221A RECOIL STARTER 16 2 1 5943 RECOIL HANDLE 16 2 2 5942 221 RECOIL COVER 16 3 260801 CABLE CLIP 17 STARTER MOTOR ASSEMBLY 17 1 97459 STARTING MOTOR 1...

Page 28: ...28 Westinghouse Outdoor Power Equipment LLC EXPLODED VIEWS GENERATOR EXPLODED VIEW...

Page 29: ...L TANK CONNECTING PIPE 6 7 94423 FUEL LINE CLAMP 7 PANEL ASSEMBLY 7 1 91327 BOLT M6 7 2 714386 PANEL 7 2 1 6022 ENGINE SWITCH 7 2 2 6041 TIME ACCUMULATOR NO PART DESCRIPTION 7 2 3 6434 22 BREAKER 7 2...

Page 30: ...NO PART DESCRIPTION 11 11 91323 BOLT M5 11 12 91513 BOLT M5 11 13 90009 NUT M5 11 14 532303 052 TAIL BRACKET FIXING PLATE 11 15 94204 SPRING WASHER 12 CO MODULE ASSEMBLY 12 1 599063 CO MODULE 12 2 922...

Page 31: ...Westinghouse Outdoor Power Equipment LLC 31 SCHEMATICS SCHEMATICS SCHEMATICS...

Reviews: