45
WHL-012 REV. 12.17.14
Press the
button again to return to Operation Mode.
NOTE:
The Control System will not allow the changes if Lock Mode is activated. Lock Mode will have to be turned off before making
further changes.
Parameter
Detail
Description
O: ot
Outdoor temperature
Current outdoor sensor temperature
A: Li or A: GA
DHW Water flow rate
Current flow (Li: LPM, GA: GPM)
b: It
CH return water temperature
Current CH return water temperature
C: Fr
FAN speed (RPM)
Current fan speed (RPM)
d: Lc
Lock function (Lock)
Lock Mode “ON”/”OFF”
E: oP
CH supply temperature (Operating temperature)
Current CH supply temperature
F: dH
DHW outlet temperature
Current DHW outlet temperature
H: Eh
Exhaust temperature
Current exhaust temperature
I: St
N/A
Not Used (Default is 0)
Parameter
Detail
Description
J: oH
CH water overheat temperature
Current temperature on the overheating sensor.
L: rt
1: PH
Burner Operation
Time
Supply power time
L:rt
display on
sub menu
Unit : 100 hour
2: rh
Burner operation time
Unit : 1 hour
3: rH
Burner operation time
Unit : 1,000 hour
4: It
Ignition cycles
Cycle : 10 times
5: IH
Ignition cycles
Cycle : 10,000 times
P: Ou
Displays output condition for internal primary pump and
three way valve.
- Off
- On
1
st
Icon
2
nd
Icon
3
rd
Icon
Not Used
Internal
Primary Pump
3 Way
Valve
Table 19
– Status Mode Display Screen Descriptions
I. INSTALLER MODE
Installer Mode will activate when the
button is pressed and held for five seconds while the display is powered OFF. If the display is
powered on, press the
button to turn it off before pressing and holding the
button for five seconds.
Figure 36
– Installer Mode Screens
Toggle through items that can be viewed/changed by turning the dial
. To view/change an item, press the
button. Some
displayed items can be changed by turning the dial
counterclockwise to lower and clockwise to raise the displayed value. Press the
button again to save settings.
To leave Installer Mode, press the
button again. The display will return to power off mode.
Display
Default
Detail
Description
1: EH
E0:00
Error history up to 10
Check last 10 error codes (E0 - E9)
2: cE
OFF
Delete Error history
Select “ON” to delete error code history
Range: ON or OFF
3: In
OFF
Initialized system
Select “ON” to reset to factory setting
(Burner operation time, Ignition cycles, and Supply power time will not be
reset)
Range: ON or OFF
4: Fu
GA
Change unit for water
volume
Range: GA or Li