Lit. No. 28270, Rev. 00
July 1, 2005
88
PUMP PRESSURE TEST
NOTE: Reservoir will contain
residual pressure. Loosen, then
retighten, breather to release
pressure before proceeding.
1. Verify proper fluid level before
beginning test.
2. Install a tee in line with the right
rod end ram hydraulic hose and
attach a 3000 psi pressure gauge.
3. Activate the right retract function.
Read the pressure once the
blade is fully retracted while
continuing the right retract
command.
4. Refer to Relief Valve Inspection
and Adjustment section for valve
location and adjustment
instructions.
Is motor draw greater than
190 amps at pump relief?
Is pump relief pressure
1750 ± 50 psi?
Adjust pump relief 1/4 turn
to increase pressure. Did
pressure change?
Adjust to 1750 ± 50 psi.
YES
YES
NO
NO
Inspect pump relief valve
for damaged components
or contamination. Is pump
relief valve OK?
Remove pump. Is pump
O-ring damaged.
YES
Go to
Relief Valve
Inspection and
Adjustment.
NO
Replace pump.
Replace pump O-ring.
Reassemble and adjust
pressure.
YES
NO
NO
YES
Repair or replace motor.
Go to
Hydraulic System
Test.
Right Rod
End Hose
Pressure
Gauge
RIGHT
SECONDARY
BLOCK ASSY.
HOSE
GAUGE
TEE
MOVEMENT
BLADE
RIGHT
RETRACT
MOTOR
M
ON