Lit. No. 72444, Rev. 05
116
April 1, 2021
MAINTENANCE
FUSE REPLACEMENT
The vehicle control harness contains two
automotive-style fuses. The snowplow park/turn
power and control power are covered by individual
10A fuses. The control fuse is "hot" when the
vehicle ignition switch is ON and the electrical
connections to the snowplow are completed.
The MVP PLUS™ and MVP 3™ hydraulic unit
harness systems contain four automotive-style
fuses. The 3-solenoid harness (to port B on the
hydraulic unit module) and 8-solenoid harness (to
port C) each contain two 4A fuses.
The WIDE-OUT™ and WIDE-OUT™ XL
hydraulic unit harness system contains four
automotive-style fuses. The 2-solenoid harness
(to port B on the hydraulic unit module) and
6-solenoid harness (to port C) each contain two
4A fuses.
The ENFORCER™ hydraulic unit harness system
contains one 5A fuse in the 3-coil port C harness,
and two 5A fuses in the 4-coil port B harness.
The PRODIGY™, HTS™, and straight blade
hydraulic unit harness systems contain two
4A automotive-style fuses in the 3-solenoid
harness (to port B on the hydraulic unit module).
The DEFENDER™ compact plow's vehicle control
harness contains one 2A automotive-style
fuse and the hydraulic unit contains two
4A automotive-style fuses.
Your system may also include a 200A fuse
between the battery and vehicle battery cable.
If a problem should occur and fuse replacement
is necessary, the replacement fuse must be of the
same type and amperage rating as the original.
Installing a fuse with a higher rating can damage
the system and could start a
fi
re.