![Western MIDWEIGHT Installation Instructions Manual Download Page 15](http://html.mh-extra.com/html/western/midweight/midweight_installation-instructions-manual_960595015.webp)
Lit. No. 64369, Rev. 04
15
June 15, 2010
INSTALLATION INSTRUCTIONS
Fittings and Hoses
The hydraulic
fi
ttings and hoses are found in the
hydraulics box.
1. Remove port plug from lift ram and install a
90° SAE O-ring
fi
tting oriented toward the
passenger's side.
2. Install 45° SAE O-ring
fi
ttings oriented
approximately 20° to the rear from inward straight
facing position.
3. Remove three large port plugs from the
passenger's side of the hydraulic unit valve block
and install 90° SAE O-ring
fi
ttings oriented down,
parallel with short edge of valve block.
4. Remove the 3/8" NPTF square head pipe plug
from the front side of valve block and install
3/8" NPTF street elbow oriented up. Install
3/8" NPTF breather in elbow.
5. Attach 16" hydraulic hose to front
fi
tting on valve
block and lift ram.
6. With a marker or piece of tape, mark the center of
each 42" hydraulic hose.
7. Attach a 42" hydraulic hose to center
fi
tting
on valve block. Route hose down over lower
cross tube behind lift frame and attach to
passenger-side angle ram.
8. Attach a 42" hydraulic hose to rear
fi
tting on valve
block. Route hose down over lower cross tube
behind lift frame and attach to driver-side angle
ram.
Passenger-Side
Hose
Driver-Side
Hose
Lift Ram Hose
Lift Ram
Fitting
Top Driver-Side View
Approx.
20°
Angle Ram
45° SAE
O-Ring Fitting
3/8" NPTF
Breather
3/8" NPTF
Street Elbow
90° SAE
O-Ring
Fitting (3)