B.
Specifications
Interface:
16 RS-232C serial inputs use RJ-11 connectors,
which require 4-wire straight RJ-11 cables and modular
adapters and 6-wire cable if using CTS/DTR flow control.
Distance:
750 feet maximum at 9600 baud, for each port.
Coding:
Asynchronous, 7/8 bits ASCII.
Parity:
Even, Odd, None
Stop Bits:
1 or 2.
Data Rate:
300 to 38.4K BPS (all standard rates).
Flow Control:
XON/XOFF, CTS/DTR, Both, or None.
Timeout:
No activity timeout disconnects port. None, 1, 5, 10,
15 seconds, 1, 5, 15, 30 minutes.
Memory:
Non-volatile 256K (512K optional) battery-backed
SRAM. Auto configuring, dynamically allocated.
Setup Switch:
8 position, sets default parameters for baud rate,
flow control and port mode.
LEDs:
Power On, Ready, Data Activity for Ports 1-16.
Temperature:
0
°
C to 50
°
C (operating)
Power:
Internal 115/230 VAC 50/60 Hz, 5 watts
Size:
1.75" x 17.0" x 6.5" (H x W x D)
Weight:
6 lbs. shipping weight