Warnings and Cautions:

Installation Instructions

Secure Racking

If Secure Racked units are installed in a closed or multi-unit rack assembly, they may require further 

evaluation by Certification Agencies.  The following items must be considered.
1.  The ambient within the rack may be greater than room ambient.  Installation should be such 

that the amount of air flow required for safe operation is not compromised.  The maximum 

temperature for the equipment in this environment is 45°C.  Consideration should be given to the 

maximum rated ambient.

2.  Installation should be such that a hazardous stability condition is not achieved due to uneven 

loading.

Input Supply

1.  Check nameplate ratings to assure there is no overloading of supply circuits that could have an 

effect on overcurrent protection and supply wiring.

2.  When installing 48 VDC rated equipment, it must be installed only per the following conditions:

A.  Connect the equipment to a 48 VDC supply source that is electrically isolated from the 

alternating current source.  The 48 VDC source is to be connected to a 48 VDC SELV source.

B.  Input wiring to terminal block must be routed and secured in such a manner that it is 

protected from damage and stress.  Do not route wiring past sharp edges or moving parts.

C.  A readily accessible disconnect device, with a 3 mm minimum contact gap, shall be 

incorporated in the fixed wiring.

Grounding

Reliable earthing of this equipment must be maintained.  Particular attention should be given to 

supply connections when connecting to power strips, rather than direct connections to the branch 

circuit.

No Serviceable Parts Inside; Authorized Service Personnel Only

Do not attempt to repair or service this device yourself.  Internal components must be serviced by 

authorized personnel only.

•  Shock Hazard - Do Not Enter

Disconnect Power

If any of the following events are noted, immediately disconnect the unit from the outlet and contact 

qualified service personnel:

1.  If the power cord becomes frayed or damaged.

2.  If liquid has been spilled into the device or if the device has been exposed to rain or water.

Summary of Contents for APS-8M

Page 1: ...WTI Part No 13499 Rev A APS 8M AsynchronousPortSwitch withInternalModem Quick Start Guide ...

Page 2: ...supply source that is electrically isolated from the alternating current source The 48 VDC source is to be connected to a 48 VDC SELV source B Input wiring to terminal block must be routed and secured in such a manner that it is protected from damage and stress Do not route wiring past sharp edges or moving parts C A readily accessible disconnect device with a 3 mm minimum contact gap shall be inc...

Page 3: ...ion Connect your Telco Line to the APS 8M Use a standard RJ 11 cable to connect your Telco outlet to the Line Port located on the APS 8M back panel Note that the unit sees the internal modem as Port 8 To connect to the Modem Port use the procedure described in Section 3 of this Quick Start Guide Connect a PC to the APS 8M Attach a standard null modem cable from your PC COM port to the Port 1 conne...

Page 4: ...not be displayed 2 Review the Help Menu At the APS Command Prompt type H and press Enter to display the Help Menu Figure 1 which provides a basic listing of all APS 8M commands 3 Port Status Screen Type S and press Enter to display the Port Status Screen Figure 2 which summarizes conditions at all APS 8M ports COMMAND MENU DISPLAY CONFIGURATION S Port Status F System Parameters SD Port Diagnostics...

Page 5: ...To connect Port 2 to Port 3 type C 2 3 Enter ii While Ports 2 and 3 are connected Port 1 will still recognize APS commands Type S Enter to display the Port Status Screen The STATUS column should now list Ports 2 and 3 as connected and Port 1 as Free iii Issue a Third Party Disconnect command to disconnect Ports 2 and 3 type D 2 Enter The unit will display the Are you Sure y n prompt Type y and pre...

Page 6: ...d and press Enter If a Supervisor Level password has not yet been defined the prompt will not be displayed a Type H and press Enter to display the Help Menu If desired you may also wish to repeat the Port Connection Disconnection examples described in Step 4 above b When you have finished communicating with the APS 8M unit type X and press Enter to exit command mode and terminate the modem connectio...

Page 7: ...ly approved by the party responsible for compliance could void the user s authority to operate the equipment EMC Safety and R TTE Directive Compliance The CE mark is affixed to this product to confirm compliance with the following European Community Directives Council Directive 89 336 EEC of 3 May 1989 on the approximation of the laws of Member States relating to electromagnetic compatibility and Co...

Page 8: ...5 Sterling Irvine California 92618 949 586 9950 Toll Free 1 800 854 7226 Fax 949 583 9514 http www wti com ...

Reviews: