Western Global FuelCube FCP1000 Operator'S Manual Download Page 7

 

 

 

 3

 

USE

R’S NOTICE 

 

 

The 

FUEL

CUBE

TM

 is designed for the storage of diesel fuel 

– UN 1202 / UN 1993. Other 

fuels may also be stored in accordance with UL approval. Closed top diked tank. 

 

 

The 

FUEL

CUBE

TM

 is a double-walled UL-142 and ULC S-601 diked tank. 

 

 

For use on site as a stationary tank, the 

FUEL

CUBE

TM

 is UL 142 listed for fuel storage  

 

 

Fill to a maximum of 95% capacity. 

 

 

Regulation size placards must be on all four (4) sides of the 

FUEL

CUBE

TM

 or its means 

of transport, if being transported uncleaned. 

 

 

Closures:  During  transport  of  uncleaned  tanks,  all  valves  and  plugs  must  be  closed. 
Ensure pump is turned off.  The closure system nearest the contents of the tank must be 
closed first.  Close and lock the hatch lid. 

 
 

 

Replacement  of  any  component  must  be  the  same  specifications  or  equivalent.  
Replacement parts can be obtained from Western:  
USA Toll Free: 866-814-2470 | Fax: 203-847-4310  |  Email: [email protected] 

Canada Toll Free: 1-866-588-2637 | Fax: 204-772-6597 | Email: [email protected]

 

 

 

Refer to 

Operator’s Manual

 for more details.  The operator must read and understand 

Manual before using the 

FUEL

CUBE

TM

 
MANUFACTURER’S LIMITED WARRANTY 

 

This warranty is in substitution of every warranty as to quality fitness or description expressed or 
implied by statute, common law or custom. 

 

WESTERN products are fully guaranteed for a period of five (5) years from the date of purchase 
against faulty workmanship or material.  Faulty products should be returned by the customer to 
the supplier.  The supplier will replace or repair any faulty item free of charge, providing there are 
no obvious signs of abuse or indication that the equipment has not been used in accordance with 
the  Manual  or  instructions,  and  where maintenance  is  required  this  has been  duly  carried  out.  
The above warranty covers only components made by WESTERN.  Any components that are not 
of 

WESTERN’s manufacture are covered by the original manufacturer’s guarantee. 

 

Pump, hose and nozzle are subject to Manufacturer Warranty. 

 

WARRANTY  DOES  NOT  COVER:  wear  and  tear  caused  by  normal  use,  damage  caused  by 
accident, abuse, off road use, faulty installation, misapplication, improper maintenance, violations 
of product manuals, warnings, misuse of operation instructions, or Acts of God. 

 

UNDER  NO  CIRCUMSTANCE  can  WESTERN  be  liable  for  any  charges  in  respect  of  labor, 
indirect losses, consequential damage, loss of profit, loss of product, inability from use of product 
for any purpose whatsoever and all such fees and litigation. 

 

WESTERN cannot be held liable for any misinterpretation of information given in this book.   
 

Summary of Contents for FuelCube FCP1000

Page 1: ...OPERATOR S MANUAL MODEL NO...

Page 2: ......

Page 3: ...TABLE of CONTENTS...

Page 4: ......

Page 5: ...the Operator s Manual This manual covers the FUELCUBETM Models FCP250 FCP500 and FCP1000 Please use the Table of Contents or the Index as guides to locate required information Keep this manual handy...

Page 6: ...mber of your FUELCUBETM when ordering parts or requesting service or other information The serial number plate is located where indicated in the image below Please mark the number in the space provide...

Page 7: ...ty as to quality fitness or description expressed or implied by statute common law or custom WESTERN products are fully guaranteed for a period of five 5 years from the date of purchase against faulty...

Page 8: ......

Page 9: ...an imminently hazardous situation that if not avoided will result in death or serious injury This signal word is to be limited to the most extreme situations typically for machine components which for...

Page 10: ...uctions in the manual and to follow these Most accidents can be avoided A person who has not read and understood all using and safety instructions is not qualified to use the machine An untrained oper...

Page 11: ...ons and of how it works Review the safety instructions with all users annually 6 This equipment is dangerous to children and persons unfamiliar with its operation The operator should be a responsible...

Page 12: ...xisting workers Be certain only a properly trained and physically able person will use the machinery A person who has not read and understood all using and safety instructions is not qualified to use...

Page 13: ...nly in daylight or good artificial light 5 Be sure machine is properly mounted adjusted and in good using condition 6 Ensure that all safety shielding and safety signs are properly installed and in go...

Page 14: ...9 When completing a maintenance or service function make sure all safety shields and devices are installed before placing unit in service 10 Establish a lock out tag out policy for the work site Be su...

Page 15: ...ous safety signs the type of warning and the area or particular function related to that area that requires your SAFETY AWARENESS THINK SAFETY WORK SAFELY SECTION 3 B A A B REMEMBER If safety signs ha...

Page 16: ...12...

Page 17: ...tors are not qualified to use the machine In addition to the design and configuration of equipment hazard control and accident prevention are dependent upon the awareness concern prudence and proper t...

Page 18: ...transfer fuel and the nozzle hooks to the side frame Power must be supplied by the customer to power the pump Output and return line with valves can be connected to an engine operating at a remote lo...

Page 19: ...checked After Using for 1 and 5 Hours Check all nuts bolts and other fasteners Tighten to their specified torque level Check that the fuel lines and connections are in good condition and there are no...

Page 20: ...at would melt Keep it in good condition Replace cap if it is damaged in any way c The outer tank is vented to atmosphere through the hose slots under the lid Do not obstruct in any way 3 FILLING FUELC...

Page 21: ...ce FUELCUBETM in a level area adjacent to the engine requiring fuel b Install quick couplers into the tank outlets appropriate for your application The feed or return ports are marked with directional...

Page 22: ...up any spills j Disconnect the power to the pump k Store the hose into the bund and hook the nozzle to the storage bracket l Close and lock the hatch lid m Move to the next refueling location 7 FORKL...

Page 23: ...s and replace any broken components with genuine replacement parts of their equivalent a During Fuel Transfers Someone needs to be in attendance when filling the FUELCUBETM or transferring fuel Always...

Page 24: ...h owner and user of the FUELCUBETM should review this manual as part of the regular training and review procedure Follow all instructions 1 Remove the corner brackets and bolts from each side 2 Screw...

Page 25: ...after having read through this trouble shooting section please call your local Western distributor or dealer Before you call please have this Operator s Manual from your unit and serial number ready P...

Page 26: ...22...

Page 27: ...TRIC MM LENGTH WIDTH HEIGHT FCP250 203 243 921 926 420 2956 1341 44 1117 44 1117 45 5 1156 FCP500 440 528 2000 1495 678 5904 2678 85 7 2178 44 5 1130 45 5 1157 FCP1000 846 1016 3846 3201 1452 11680 52...

Page 28: ...5 220 3 4 225 165 390 290 540 400 7 8 230 170 570 420 880 650 1 345 225 850 630 132 970 Torque figures indicated above are valid for non greased or non oiled threads and heads unless otherwise specifi...

Page 29: ...ght fittings to torque shown 6 Tighten while holding body of fitting with a wrench Tube Size OD Nut Size Across Flats Torque Value Recommended Turns to Tighten After Finger Tightening in in N m lb ft...

Page 30: ...26...

Page 31: ...oring 7 19 Nozzle Optional 3 9 14 15 16 17 18 19 Operating Safety 9 Operating Responsibility 13 16 Orientation 1 OSHA 6 Outer Tank 9 10 14 16 17 18 20 Parts and Service 3 8 11 14 19 Placards TDG 3 10...

Page 32: ...70 toll free p 1 203 847 4300 WESTERN GLOBAL UK w www western global uk com e sales western global uk com p 44 1454 227 277 WESTERN GLOBAL AUSTRALIA w www transtank com e enquiries transtank com au p...

Reviews: