WARNING - REDUCE THE RISK OF FIRE
To reduce the risk of fire, use only telecommunication line cords with a
cable diameter of AWG 26 or larger. Regarding power cable dimensions,
see Interface Specifications.
CAUTION - HANDLING OF SFP TRANSCEIVERS
SFP transceivers are supplied with plugs to avoid contamination inside the
optical port. They are very sensitive to dust and dirt. If the fibre is
disconnected from the product, the protective plugs on the transmitter/
receiver must be connected. The protective plugs must be kept on during
transportation. The fibre optics cables must be handled the same way.
CAUTION - CORROSIVE GASES
If the product is placed in a corrosive environment, it is important that all
unused connector sockets are protected with a suitable plug, in order to
avoid corrosion attacks on the gold plated connector pins.
CAUTION - ELECTROSTATIC DISCHARGE (ESD)
Prevent electrostatic discharge damages to internal electronic parts by
discharging your body to a grounding point (e.g. use a wrist strap).
CAUTION - HOT SURFACE
Be aware of that the surface of this product may become hot. When it is
operated at high temperatures, the external surface may exceed Touch
Temperature Limit according to the product's relevant electrical safety
standard.
CAUTION - CABLE TEMPERATURE RATING FOR FIELD
TERMINAL WIRES
There may be a requirement on the minimum temperature rating of the
cable to be connected to the field wiring terminals, see Interface
Specifications.
6
Lynx L105-S1 and L205-S1