Environmental
phenomena
Basic standard
Description
Test levels
RS-232 port to all
other ports
Table 9. EMC and electrical conditions
Environmental
phenomena
Basic
standard
Description
Test levels
Temperatures
EN 60068-2-1
EN 60068-2-2
Operational
-40 to +70°C (-40 to +158°F)
a
Storage and
transport
-50 to +85°C (-58 to +185°F)
Humidity
EN 60068-2-30
Operational
5-95% relative humidity
Storage and
transport
Altitude
Operational
2000 m/70 kPa
Service life
Operational
10 years
MTBF
MIL-C217F2,
Parts count
677,000 hours
Vibration
IEC 60068-2-6
(sine)
Operational
3 - 13.2 Hz: 1 mm
13.2 - 100 Hz 0.7 g
5.5 - 30 Hz: 1.5 g
30 - 50 Hz: 0.42 mm
50 - 500 Hz: 4.2 g
b
IEC
60068-2-64
(random)
5 - 20 Hz: 2 m
2
/s
2
20 - 2000 Hz - 3 dB/oct
Shock
IEC
60068-2-27
Operational
30 g, 11 ms
100 g, 6 ms
b
Bump
IEC
60068-2-27
Operational
10 g, 11 ms
Enclosure
EN 60950-1
Zinc
Fire enclosure
Weight
0.7 kg
Degree of protection
EN 60529
Enclosure
IP40
Cooling
Convection
a
Refer to "Safety and Regulations" chapter regarding touch temperature
b
Might require Ethernet cables to be fastened close to the unit.
Table 10. Environmental and mechanical conditions
24