2.2. Safety Information
Before installation:
Read this manual completely and gather all information available on the product. Make sure
it is fully understood. Check that your application does not exceed the safe operating
specifications for the product.
WARNING - SAFETY DURING INSTALLATION
The product must be installed and operated by qualified service personnel
and installed into an apparatus cabinet or similar, where access is
restricted to service personnel only.
During installation, ensure a protective earthing conductor is first
connected to the protective earthing terminal (only valid for metallic
housings). Westermo recommends a cross-sectional area of at least 4
mm
2
.
If the product does not have a protective earthing terminal, then the DIN-
rail must be connected to protective earth. Upon removal of the product,
ensure that the protective earthing conductor, or the connection to earth
via the DIN-rail, is disconnected last.
WARNING - HAZARDOUS VOLTAGE
Do not open an energized product. Hazardous voltage may occur when
connected to a power supply.
WARNING - PROTECTIVE FUSE
It must be possible to disconnect manually from the power supply. Ensure
compliance to national installation regulations.
Replacing the internal fuse must only be performed by Westermo qualified
personell.
WARNING - POWER SUPPLY CONNECTION
There are safety regulations on which power sources that shall be used in
conjunction with the product. Refer to Interface Specifications.
Lynx L105-S1 and L205-S1
5