installation instructions
Your spa is equipped with one massage pump,
one diverter and several air valves, allowing you to
run the various parts of the jet system separately
or together. Do not connect an empty spa to the
electricity supply. This can damage components
such as the control unit, heater, circulation pump
and other parts of the system.
PREPARING THE SITE
1. INSTALLATION INDOORS/IN A BASEMENT
When placing your spa indoors a number of particular conditions
need to be observed. The floor around the spa will become wet and
must therefore provide a good grip when moist. Correct drainage is
needed to prevent the accumulation of water around the spa. If you
are building a new room for the spa, we recommend that you install
a drain in the floor. Humidity levels will rise with the spa installed,
which can cause fungal growth, mould and other problems. For this
reason, you should check the effect of humidity on exposed wood,
wallpaper, etc., in the room. To minimise these effects, thorough
ventilation of the area around the spa is advised.
2. INSTALLATION OUTDOORS AND ON PATIOS/BALCONIES
It is important to install the new spa on a stable base. To be certain
that your wooden deck or base can cope with the spa you must
check the maximum load of the deck. Consult a qualified builder or
designer for advice. The weight of the spa and its contents, and the
maximum number of users, can be found in the specifications for
the spa. This weight per square metre must not exceed the nom-
inal capacity of the structure, as otherwise serious damage to the
structure may result. If you install the spa outdoors, we recommend
a reinforced concrete plate with a thickness of at least 10 cm. Do not
forget to provide sufficient runoff around the spa to ensure that water
will run away during heavy rain, for example. Try to protect the spa
from rain and snow and, if possible, build a conservatory for the spa.
servicing and installation
must be performed by a
qualified technician.
Basic guidelines for installation and configuration
On installation, an access route must be prepared for when discon-
necting.
Permanently connected. Connect only to a circuit that is protected
by an RCD and an isolating switch.
See the circuit diagram on the inside of the lid of the control unit.
See the installation and safety instructions.
NB:
• People with infectious conditions should not use the spa.
• To avoid injury, take care when getting into and out of the spa.
• Do not use the spa immediately after performing strenuous
exercise.
• Prolonged bathing in the spa can be damaging to health.
• Ensure that the chemical levels of the water are kept in accord-
ance with the manufacturer’s instructions.
RCD
The owner must regularly test and reset the RCD to ensure that it is
working.
Risk of electric shock!
No electrical components should be maintained by the user.
Do not try to carry out maintenance work on the control system.
Contact Westerbergs and our service organisation. Follow all instruc-
tions for the owner’s manual electrical connections. In order for the
product warranty to remain valid, the installation must be carried
out by an authorised electrician and all earth connections must be
installed correctly.
BASIC RULES
The spa must be installed such that service employees can gain
access from all sides if necessary. It is the customer's responsibility
to ensure that the spa is accessible and, if necessary, to remove/
move any obstacles or housings/sunken installation constructions to
secure access to the spa.
Any time that a service employee spends (if possible) on gaining
access to the spa is debited at the applicable hourly rate for each full
or partial hour.
Caution:
• Read the instructions.
• Test the RCD each time before using the spa bath.
• Sufficient drainage must be provided if the equipment is to be
installed in a pit.
• Connect only to a circuit that is protected by an RCD and an
isolating switch.
• For continued protection against electric shock, use only
identical replacement components when servicing.
• Water temperatures exceeding 38°C can be damaging to health.
• Disconnect from the power supply before servicing. Always keep
all hatches in the panel closed except during servicing.
installation
1. Read the user manual carefully and have the spa installed and
configured by a professional.
N.B. Prior to installation, an isolating switch and a separate RCD
must be installed.
2. Check that all bolted joints on the pumps and the heater are
properly tightened as they can come loose during transit and
cause leakage.
Leakage due to insufficiently tightened joints is not covered by
the warranty. Also refit the bolted joint on the compressor, which
is removed for transit (only Luxury).
3. Move the spa to the prepared area and remove the packaging.
We recommend using ground styrofoam under the spa which
further insulates from ground cooling.
4. Open the electronic box to prepare the connection of power.
Prepare a cable, long enough for connection to the electronic
box. Put the cable inside the electronic box through the
capsulated hole.
5. Clean and wax the spa and lid. The spa has been thoroughly
testing during the manufacturing process to ensure that it works
correctly. There may, therefore, be small amounts of water and
possibly a certain amount of lubricant grease remaining in the
pipes after testing. This may have left
stains on the spa, lid or
sides. You must therefore clean it using water and then mop it
clean using a soft rag or a cleaning agent designed for acrylic
plastic before waxing if possible.