USER Section
(en)
7729500 (03-12/19)
270
Overheating exchanger
Call the Authorised Service Centre.
317 162
Call the Authorised Service Centre.
Call the Authorised Service Centre.
321 163
Call the Authorised Service Centre.
Call the Authorised Service Centre.
384 164
Parasite flame (internal error)
Press and hold down for at least 2 seconds.
385 165
Input voltage too low
Automatic reset at voltages in excess of 175V. If this fault
persists, call the Authorised Service Centre.
431
Exchanger sensor faulty
Call the Authorised Service Centre.
In the event of a fault, the display backlighting indicates the error code. 5 reset attempts can be performed after which the
boiler shuts down. Wait 15 minutes before attempting to reset the boiler again.
5. BOILER INFORMATION MENU
Press and hold down for at least 1 second, to display the information indicated in the table. Press to exit.
DESCRIPTION
DESCRIPTION
00
Secondary fault internal code
06
Heating return temperature (°C)
01
Heating supply temperature (°C)
07
Flue sensor temperature (°C)
02
Outdoor temperature (°C)
08
Primary exchanger temperature (°C)
03
Indirect tank DHW temperature (boiler CH only)
09 - 13
Manufacturer information
04
Domestic hot water temperature
(boiler with plate exchanger)
14
Identification Open Therm communication
05
Water pressure in heating system (bar)
15 - 18
Manufacturer information
6. SWITCHING OFF THE BOILER
To turn off the boiler, disconnect the electric power supply using the two-pole switch. In the “Off” operating mode the boiler stays
off but the electrical circuits remain powered and the anti-freeze function remains active.
7. FILLING THE SYSTEM
To fill the system, pull out the telescopic tap
“A”
at the bottom of the boiler and slowly turn it anti-clockwise (do NOT use tools)
until the pressure, with the system cold, ranges from 1 and 1.5 bar (see pressure gauge
“B”
- figure to side). After the required
pressure is reached, close the filling tap.
Regularly check that the pressure displayed on the pressure gauge
"B"
is 1 - 1.5 bar, with the boiler cold. If the pressure is too
low, turn tap
"A"
to fill the boiler.
If the system pressure is too high, open the drain tap
“C”
at the bottom of the boiler (figure to side).
A
Boiler/system filling tap
B
Pressure gauge
C
Boiler/system drain tap
Take special care when filling the heating system. In particular, open any
thermostat valves in the system, ensure the water enters slowly in order to
prevent the formation of air inside the primary circuit until operating pressure
is reached. Lastly, vent any radiators in the system. WESTEN declines all liability for
damage deriving from the presence of air bubbles in the primary exchanger due to the
incorrect or imprecise observance of the above.
The boiler is fitted with a hydraulic pressure gauge which prevents the boiler
from working if there is no water.
If pressure drops occur frequently, have the boiler checked by the
AUTHORISED TECHNICAL SERVICE CENTRE.
8. ROUTINE MAINTENANCE INSTRUCTIONS
To keep the boiler efficient and safe, have it checked by the Authorised Service Centre at the end of every operating period.
Careful servicing ensures economical operation of the system.
7712380
Summary of Contents for Star Condens+
Page 43: ...43 e l 7729500 03 12 19 1 6 1 2 Reset SI US 1 1 C 20 C 10 2 1 C 1 2 3...
Page 55: ...55 e l 7729500 03 12 19 17 4 SECTION F 17 5 CO2 CO2 6 On 3 303 3 1 ESC 18 90...
Page 59: ...59 e l 7729500 03 12 19...
Page 60: ...7729500 03 12 19 60 S E C T I O N A 7729514...
Page 66: ...7729500 03 12 19 66 S E C T I O N C 7218789 01 53 5 41 5...
Page 67: ...67 S E C T I O N C 7729500 03 12 19 53 5 41 5 A 168 5 53 5 41 5 A 168 5 130 22 22...
Page 68: ...7729500 03 12 19 68 S E C T I O N D 25 mm...
Page 71: ...71 S E C T I O N F 7729500 03 12 19...
Page 72: ...7729500 03 12 19 72 S E C T I O N F 7715701 4 5 1 CG_2522...
Page 73: ...73 S E C T I O N G 7729500 03 12 19...
Page 75: ...75 7729500 03 12 19...