7729500 (03-12/19)
6
USER Section
(en)
2. PROLONGED SHUTDOWN. ANTI-FREEZE PROTECTION
Do not drain the whole system as filling up with water again could cause unnecessary and harmful scale to build up inside the
boiler and the heating elements. If the boiler is not used during winter and is therefore exposed to the danger of frost, add some
specific anti-freeze to the water in the system (e.g.: propylene glycol coupled with corrosion and scale inhibitors). The electronic
boiler management system includes a “frost protection” function for the heating system which, when delivery temperature falls
below 5°C, lights the burner until a delivery temperature of 30°C is reached.
The function is operative if: the boiler is electrically powered, there is gas, system pressure is normal and the boiler is not
blocked.
3. GAS CONVERSION
Not supported for this type of gas boyler.
4. FAULTS
The faults shown on the display are identified with the symbol and a number (fault code). For a
complete list of faults, see the following table.
If appears on the display the fault must be RESET by the user.
To RESET the boiler, press and hold down
for 2 seconds. If faults are displayed frequently, call the
Authorised Service Centre.
Description of fault
Action
09
Gas valve connection error
Call the Authorised Service Centre.
10
External probe sensor faulty
Call the Authorised Service Centre.
12
Hydraulic differential pressure switch switching failure
Call the Authorised Service Centre.
13
Hydraulic differential pressure switch contacts stuck
Call the Authorised Service Centre.
15
Gas valve control error
Call the Authorised Service Centre.
18
Hydraulic circuit automatic filling in progress
Wait for the end of the filling cycle
19
Fault in system filling phase
Press and hold down for at least 2 seconds.
20
NTC flow sensor faulty
Call the Authorised Service Centre.
28
NTC fumes sensor faulty
Call the Authorised Service Centre.
40
NTC return sensor faulty
Call the Authorised Service Centre.
50
NTC domestic hot water sensor faulty
(only for heating-only model with storage boiler)
Call the Authorised Service Centre.
53
Fumes outlet obstructed
Disconnect the boiler from the mains power supply for a few
seconds. If the fault persists, call the authorised technical
service centre
55
Electronic board not calibrated
Call the Authorised Service Centre.
83…87
Communication problem between boiler board and control
unit. Probable short circuit on wiring.
Call the Authorised Service Centre.
92
Fumes fault during calibration (probable fumes recirculation)
Call the Authorised Service Centre.
109
Air in boiler circuit (temporary fault)
Call the Authorised Service Centre.
110
Safety thermostat tripped due to overtemperature (pump
probably blocked or air in heating circuit).
Press and hold down for at least 2 seconds.
117
Pressure in hydraulic circuit too high (> 2,7 bar)
Call the Authorised Service Centre.
118
Pressure in hydraulic circuit too low
Check that the pressure in the system is correct; See the
FILLING THE SYSTEM section.
125
No circulation safety trip
(control performed via a temperature sensor)
Press and hold down for at least 2 seconds.
128
No flame
Press and hold down for at least 2 seconds.
129
Loss of flame at ignition
Call the Authorised Service Centre.
130
Fumes NTC tripped due to overtemperature
Press and hold down for at least 2 seconds.
133
Ignition failure (5 attempts)
Press and hold down for at least 2 seconds.
134
Gas valve blocked
Press and hold down for at least 2 seconds.
135
Internal board error
Press and hold down for at least 2 seconds.
154
Delivery/return probe control test
Call the Authorised Service Centre.
160
Fan fault
Call the Authorised Service Centre.
178
Intervention of safety thermostat for excess temperature in
low temperature system
Call the Authorised Service Centre.
Summary of Contents for Star Condens+
Page 43: ...43 e l 7729500 03 12 19 1 6 1 2 Reset SI US 1 1 C 20 C 10 2 1 C 1 2 3...
Page 55: ...55 e l 7729500 03 12 19 17 4 SECTION F 17 5 CO2 CO2 6 On 3 303 3 1 ESC 18 90...
Page 59: ...59 e l 7729500 03 12 19...
Page 60: ...7729500 03 12 19 60 S E C T I O N A 7729514...
Page 66: ...7729500 03 12 19 66 S E C T I O N C 7218789 01 53 5 41 5...
Page 67: ...67 S E C T I O N C 7729500 03 12 19 53 5 41 5 A 168 5 53 5 41 5 A 168 5 130 22 22...
Page 68: ...7729500 03 12 19 68 S E C T I O N D 25 mm...
Page 71: ...71 S E C T I O N F 7729500 03 12 19...
Page 72: ...7729500 03 12 19 72 S E C T I O N F 7715701 4 5 1 CG_2522...
Page 73: ...73 S E C T I O N G 7729500 03 12 19...
Page 75: ...75 7729500 03 12 19...