Parameter
Description of
parameters
Factory settings
Parameter
Description of
parameters
Factory settings
24 F - 18 F
24 F - 18 F
F19
Factory
setting
001
F44
Factory
setting
000
F20
Factory
setting
000
F45
Factory
setting
(this value depends on
valve calibration)
F21
Factory
setting
030
F22
Factory
setting
110
F46
Factory
setting
015
F23
Factory
setting
010
F47
Factory
setting
007
F24
Factory
setting
005
F48
Factory
setting
(this value depends on
valve calibration)
F25
Factory
setting
000
F26
Factory
setting
165
F49
Factory
setting
105
F27
Factory
setting
010
F50
Factory
setting
100
F28
Factory
setting
070
F51
Factory
setting
005
F29
Factory
setting
020
F52
Factory
setting
020
F30
Factory
setting
000
F53
Factory
setting
100
F31
Factory
setting
180
F54
Factory
setting
000
F32
Factory
setting
170
F55
Factory
setting
003
F33 - F34
Factory
setting
004
F56
Factory
setting
025
F35
Factory
setting
015
F57
Factory
setting
000
F36
Factory
setting
020
F58
Factory
setting
025
F37
Factory
setting
003
F59
Factory
setting
005
F38
Factory
setting
000
F60
Factory
setting
120
F39
Factory
setting
067
F61
Factory
setting
015
F40
Factory
setting
120
F62
Factory
setting
030
F41
Factory
setting
010
F63
Factory
setting
025
F42
Factory
setting
042
F64
Factory
setting
000
F43
Factory
setting
001
15. TROUBLESHOOTING SERVICE FAULTS
The faults shown on the display are identified with the symbol
“E”
and a number (fault code). For a
complete list of faults, see the following table.
If “R” appears on the display the fault must be RESET by the user.
To reset, press and hold down for at least 2 seconds. If this fault persists, call the Authorised Service
Centre.
CODE
DISPLAYED
FAULT
POSSIBLE REASON
SERVICE ACTION
E01
Shut down for ignition
failure.
•
No inlet gas pressure.
•
Ignition switch-flame sensor wire
interrupted.
•
Flame sensing electrode faulty or
incorrectly positioned.
•
Gas valve faulty.
•
Electronic board faulty.
•
Check that the gas valve is open and there is no air in
the gas supply circuit.
•
Check the gas supply pressure.
•
Check the wire is uninterrupted and makes good
contact with the flame sensing electrode and the
ignition switch.
•
Check the connections between the gas valve and the
electronic board.
•
Check the flame sensing electrode is in good
condition and in the right position (see the
POSITIONING THE IGNITION AND FLAME-
SENSING ELECTRODE section).
E02
Shut down by safety
thermostat.
•
No water in the primary circuit
(pump blocked or exchanger
obstructed).
•
Limit thermostat faulty.
•
Limit thermostat wiring
interrupted.
•
CH flow NTC probe faulty.
•
Electronic board faulty.
•
Check pump operation (unscrew the front cap and
release the pump impeller with a screwdriver).
•
Check the pump power input wiring.
•
Check that the limit thermostat is undamaged and
replace it if necessary.
•
Check the continuity of the limit thermostat wiring.
•
Check the CH flow NTC probe (*).
•
Check whether the exchanger is clogged.
E03
Board configuration error.
•
Parameter F43 has not been set
correctly.
•
Set parameter F43 with the value indicated in the
table in the SETTING PARAMETERS section.
E04
Safety error due to
ignition failure or frequent
flame loss.
•
See the reasons indicated in E01.
•
See the reasons indicated in E42.
•
See the actions indicated in E01.
•
See the actions indicated in E42.
Summary of Contents for Quasar E
Page 21: ...21 7113156 01 1 05 13 ...
Page 41: ...41 7113156 01 1 05 13 ...
Page 61: ...61 7113156 01 1 05 13 ...
Page 81: ...81 7113156 01 1 05 13 ...
Page 101: ...101 7113156 01 1 05 13 ...
Page 121: ...121 7113156 01 1 05 13 ...
Page 141: ...141 7113156 01 1 05 13 ...
Page 142: ...7113156 01 1 05 13 142 S E C T I O N A ...
Page 144: ...7113156 01 1 05 13 144 S E C T I O N A ...
Page 146: ...7113156 01 1 05 13 146 S E C T I O N B ...
Page 148: ...7113156 01 1 05 13 148 S E C T I O N B ...
Page 150: ...7113156 01 1 05 13 150 S E C T I O N C ...
Page 151: ...151 S E C T I O N C 7113156 01 1 05 13 ...
Page 152: ...7113156 01 1 05 13 152 S E C T I O N D ...