RMC-7XX-G Installation and Web UI Guide
RMC-7XX-G Web User Interface
1-800-377-8766
Page 21
Device Port Settings
Click the Ports icon
in the device’s row to open the
Port Settings
display shown in Figure 10.
Figure 10
Port Settings display for a selected device
This display lists the
Protocol
,
Enabled
status,
Internet Port
number, and
Device Port
number for
each of the device’s ports.
Any port can be disabled and re-enabled by unchecking and checking the box in the
Enabled
column and then clicking
Save
. The Internet Port numbers can be changed as needed by
selecting and retyping the field contents or using the up and down arrows to increase or decrease
the number, and then clicking the Save button. Unsaved changes to these settings can be
canceled by clicking the X at upper right to close the display.
Clicking the
Add Port
button
at lower left opens a new bottom row with blank fields to
enter the Protocol name, Internet port number, and Device port number. See Figure 11. Another
new row is created with each click of the Add Port button even if prior additions are incomplete.
Figure 11
Canceling an Add Port entry, left, and saving an added port, right
Click
Save
to complete a port addition (Figure 11 right). Click the X in the entry row to cancel
(Figure 11 left). Incomplete additions will not be saved if the display is closed.
Click the X in the upper right corner to close the display and return to Device Settings.
Click to close
Click and drag in
header bar to
move display
(Must close to
return to
Device Settings)
Click the X to cancel the port addition
Click Save to save the added port