VHF-UHF Bi-Directional Amplifier Installation and Users Guide
System Operation: 5.1 Controls Inside the ProtectLink BDA
WESTELL.COM
1-800-377-8766
Page 5-3
Factory Reset / Alarm Mute Button
The reset button on the lower right of the control panel has 3 distinct functions:
A momentary press will temporarily disable the audible annunciator in the
BDA and on the remote annunciator if one is installed. After 24 hours, the
audible alarms will be re-enabled.
A press lasting 3-8 seconds will reboot the BDA. All settings will remain. This
is similar to powering the unit off and then back on.
A press of 10 or more seconds will reset the BDA to factory defaults. This is a
way to wipe the BDA of all settings and start over.