5.3 Installation water cooled machine
All connections work must be carried out in accordance with the (German) Drinking Water laws as well as the
applicable regulations for the place of use! Also note the technical data and conditions of use in Chapter 4.3.
always use the hoses, connections and cables supplied with device for installation!
Water-cooled
ice cube makers can be installed without taking into account the minimum distances and without
provision for air circulation. However there should be distance to the wall from the back side of the machine in order
to have enough space for the connection tubes (see Fig. 5.3).
IMPORTANT:
When the device is pushed back in, the water drain tube may become bent or kinked, thus preventing
draining of the water. Please keep an eye on the tube during re-assembly.
Please connect the enclosed inlet hose (DN 8; ¾”–screwing) with the water inlet and with the water tab (cold
water-/ fresh water inlet).Make sure that the rubber sealing is well in place.
Please connect the enclosed outlet hose (DN 20) with the residual water outlet , then run the water drain
tube to the waste water system. Ensure that the tube has a continuous gradient and no bends. Without adequate
gradient of the drain tube, the storage container may overflow and cause water damage
Please connect the enclosed outlet hose (DN 10) with the cooling water outlet , then run the cooling water
drain tube to the waste water system. Ensure that the tube has a continuous gradient and no bends.
IMPORTANT:
For hygienic reasons, the outlet hoses must not be connected directly to the waste water
system (see Fig. 5.3.2).
Residual
flow-
connection
20 mm
Fresh water-
connection ¾“
Feeder
230 V, 50 Hz
Fig. 5.3: Representation of the water-cooled device connections
Cooling water drain
Drain hose
(DN 20)
Siphon with
inlet funnel
Air space
50 mm
Fig. 5.3.2: Installlation instructions for
hygienic drainage of residual water.