Installation and Connection
3-31
3
Table 3.9
5HTXLUHG5),ÀOWHUVIRUXQVKLHOGHGPRWRUFDEOHLQVWDOODWLRQVDQG
further information on conducted and radiated levels
Note:
(1)
The external RFI filters shown in table above were selected considering inverter rated input/output current specified for ND application
(normal duty cycle) and surrounding air temperature of 50 °C (122 °F). In order to optimize, take into account inverter input/output cur-
rent and surrounding air temperature in the application to define the rated current of external RFI filter to be used. For further information
contact EPCOS.
(2)
The output filter is of the sinusoidal type, i.e., the motor voltage waveform is approximately sinusoidal, not pulsed as in the aplications
without this filter.
Inverter model (with
built-in RFI filter)
External RFI filters part number
(manufacturer: EPCOS)
(1)
Conducted emission
- maximum motor
cable length
Radiated emission - category
Inverter input
Inverter output
(2)
Category C1
Without
metallic
cabinet
Inside a metallic
cabinet
CFW11 0006 S 2 O FA
B84142-A16-R122
B84143-V11-R127
250 m
C3
C3
CFW11 0007 T 2 O FA
B84143-A8-R105
B84143-V11-R127
250 m
C2
C2
CFW11 0007 S 2 O FA
B84142-A16-R122
B84143-V11-R127
250 m
C3
C3
CFW11 0010 S 2 O FA
B84142-A30-R122
B84143-V16-R127
250 m
C3
C3
CFW11 0010 T 2 O FA
B84143-A16-R105
B84143-V16-R127
250 m
C2
C2
CFW11 0013 T 2 O FA
B84143-A16-R105
B84143-V16-R127
250 m
C2
C2
CFW11 0016 T 2 O FA
B84143-A25-R105
B84143-V33-R127
250 m
C2
C2
CFW11 0024 T 2 O FA
B84143-A36-R105
B84143-V33-R127
250 m
C3
C2
CFW11 0028 T 2 O FA
B84143-A36-R105
B84143-V66-R127
250 m
C3
C2
CFW11 0033 T 2 O FA
B84143-A50-R105
B84143-V66-R127
250 m
C3
C2
CFW11 0045 T 2 O FA
B84143-D50-R127
B84143-V66-R127
250 m
C3
C2
CFW11 0054 T 2 O FA
B84143-D75-R127
B84143-V66-R127
250 m
C3
C2
CFW11 0070 T 2 O FA
B84143-D75-R127
B84143-V95-R127
250 m
C3
C2
CFW11 0086 T 2 O FA
B84143-A120-R105
B84143-V180-R127
250 m
C3
C2
CFW11 0105 T 2 O FA
B84143-A120-R105
B84143-V180-R127
250 m
C3
C2
CFW11 0003 T 4 O FA
B84143-A8-R105
B84143-V11-R127
250 m
C2
C2
CFW11 0005 T 4 O FA
B84143-A8-R105
B84143-V11-R127
250 m
C2
C2
CFW11 0007 T 4 O FA
B84143-A8-R105
B84143-V11-R127
250 m
C2
C2
CFW11 0010 T 4 O FA
B84143-A16-R105
B84143-V16-R127
250 m
C2
C2
CFW11 0013 T 4 O FA
B84143-A16-R105
B84143-V16-R127
250 m
C2
C2
CFW11 0017 T 4 O FA
B84143-A25-R105
B84143-V33-R127
250 m
C3
C2
CFW11 0024 T 4 O FA
B84143-A36-R105
B84143-V33-R127
250 m
C3
C2
CFW11 0031 T 4 O FA
B84143-A36-R105
B84143-V66-R127
250 m
C3
C2
CFW11 0038 T 4 O FA
B84143-D50-R127
B84143-V66-R127
250 m
C3
C2
CFW11 0045 T 4 O FA
B84143-D50-R127
B84143-V66-R127
250 m
C3
C2
CFW11 0058 T 4 O FA
B84143-D75-R127
B84143-V95-R127
250 m
C3
C2
CFW11 0070 T 4 O FA
B84143-A90-R105
B84143-V95-R127
250 m
C3
C2
CFW11 0088 T 4 O FA
B84143-A120-R105
B84143-V180-R127
250 m
C3
C2