Mode 3 (ID data mode 2: setup value 10) 

In  this  mode,  it  is  allowed  to  transmit  data  to  specified  GID  and  SID 
device,  in  order  to  achieve  one-to-multiple-transmission,  but  the  single 
data including specified GID and SID should not exceed 127Bytes. 
Way of transmission: 
The data will be transmitted through the order of 13

th

 byte to 32

nd

 byte. 

Example: 
Device A shows GID=AAA, SID=55, device B shows GID=BBBB, SID=88, 
device C shows GID=CCCC, SID=99. 

Device A is going to transmit a 5-byte data 0x1234567890 to B so A sends 
a 10-byte data 0x04FFBBBB881234567890, and then B receives a 5-byte 
data 0x1234567890. 

Device  A  is  going  to  transmit  a  5-byte  data  0x1234567890  to  device  C 
through 

device 

B, 

then 

device 

sends 

14-byte 

data 

0x08FFBBBB88FFCCCC991234567890, while device B will not  receive 
anything, and then device C receives a 5-byte data 0x1234567890. 

 

Mode 4 (saved ID data mode: setup value 11) 

During this mode it is allowed to pre-save the path of specified GID and 
SID.  When  sending  signals  the  system  will  automatically  follow  the 
pre-saved value to transmit, it is up to 14 times of transmission and single 
data of pre-saved GID and SID should no greater than 127 Bytes. 

  12

th

 Byte: Invalid character, fixed as 0X00 

  13

th

  to  32

nd

  Byte:  Pre-saved  path,  it  only 

activates in mode 4 (saved ID data mode). 

  13

th

 Byte: It stands for the valid data among 14~32 bytes. 

  14

th

 ~32

nd

 Bytes format of path: 

  Example 1: 04 FF 12 34 55 11 22 33 44

00 

The 13

th

 Byte shows the valid data is 4-Byte FF 12 34 55 

FF 12 34 55, it stands for GID=1234, SID=55. This device will receive 
data from UR and automatically sends to device with GID=1234 and 
SID=55. 

  Example 2: 05 FF 12 34 55 11 22 33 44

00 

The 13

th

 Byte shows the valid data is 5-Byte FF 12 34 55 11 

FF 12 34 55 11, it stands for GID=1234, SID=55 and 11. This device 
will receive data from UR and automatically sends to   

The device with GID=1234 and SID=11. 

  Example 3: 06 FF 12 34 55 11 22 33 44

00 

The 13

th

 Byte shows the valid data is 6-Byte FF 12 34 55 11 22 

FF 12 34 55 11 22, it stands for GID=1234, SID=55, 11 and 22. This 
device will receive data from UR and automatically sends to   
The device with GID=1234 and SID=55 and transferring to the device 

with GID=1234, SID=22. 

  Example 4: 08 FF 12 34 55 FF 45 67 88 44

00 

The 13

th

 Byte shows the valid data is 8-Byte FF 12 34 55 FF 45 67 88, it 

stands for GID=1234, SID=55, GID=4567 and SID=88. This device will 
receive data from UR and automatically sends to device with GID=1234 
and SID=55 and transferring to the device with GID=4567 and SID=88. 

Summary of Contents for RD-232HI-4M5W

Page 1: ...rf net tw RD 232HI HP9M Series Instruction Manual P 1 WENSHING Wireless Data Radio Modem RS232 Output 485 Output 434MHz 5W Multi point Transceiver Model RD 232HI 4M5W Version History Version Date Chan...

Page 2: ...4 View 5 General Operation 6 Stand by Installation Mode 6 Set up Installation Mode 6 Menu Items 6 Command Communication Mode 7 Modifying internal parameters through RS 485 or RS 232 interface 7 Enter...

Page 3: ...t this statement recorded by the note When consumers in contravention of this statement recorded note of the operation I am afraid our company could not shoulder any responsibility Products are defect...

Page 4: ...Channel Home Automation Standard Wireless RS232 Active RFID Base Station Transceiver Characteristic Parameter Min Type Max Unit Condition Operating Condition Operating Temperature Range 10 70 Operati...

Page 5: ...http www wenshing com tw http www rf net tw RD 232HI HP9M Series Instruction Manual P 5 View...

Page 6: ...r RSSI monitoring mode This mode sees RSSI as the priority mode there will be incomplete reception when receiving data at this mode Set up Installation Mode Set up key 1 Press set up key shortly to sw...

Page 7: ...e value 0x03 00 00 00 00 05 06 9B 68 07 00 00 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF This is original default value There will be altogether 31 bytes showing the current internal par...

Page 8: ...alue Hex Bit0 Bit2 27 0 000 29 1 001 30 2 010 32 3 011 33 4 100 35 5 101 36 6 110 37 7 111 Bit3 Bit5 Invalid character fixed as 000 Bit6 Bit7 Device working in 4 modes as stating below Mode 1 Long fig...

Page 9: ...of pre saved GID and SID should no greater than 127 Bytes 12th Byte Invalid character fixed as 0X00 13th to 32nd Byte Pre saved path it only activates in mode 4 saved ID data mode 13th Byte It stands...

Page 10: ...al apparatus wireless restriction and way of interfering with the characteristic FCC Consistent Declaration U S A Only Attention FCC rule regulation modified and changed must allowed by WENSHING Elect...

Reviews: