36
EN
PoE information (ZAC50EN0x):
The switch monitors the current PoE power consumption constantly. The webpage shows the maximum avail-
able PoE performance of the switch as well as the currently reserved and outgoing PoE performance.
Every PoE device registers in a specific PoE performance class when starting. This performance is then re-
served in the switch. Mostly, the maximum reserved performance is not demanded, however. It is possible to
optimally utilize the maximum PoE performance of the switch by deactivating the PoE performance monitoring.
If the PoE performance monitoring is switched off, the functionality of the PoE device may be impaired if the
performance required exceeds the max available PoE performance. The maximum required PoE performance
must not exceed the maximum PoE performance of the switch. If the performance monitoring is deactivated,
this is displayed on the switch with a red flashing PoE max LED. During operation, the performance monitoring
can be changed from inactive to active. Here, all PoE devices are restarted automatically in order to save the
reserved performance of the individual ports.
Change password:
An additional window opens, in which the new password can be entered.
Please note: If you forget the password, the switch can only be set to the delivery state via a reset on
the controller.
Reset:
The following settings can be reset to the delivery state by pressing the “Reset” button.
• Parameter of the digital I/O ports: All digital I/O ports are switched to input
• Parameter PoE: PoE monitoring is switched to one and on all ports
the PoE power supply is activated
• The password is reset to the delivery state (“admin”)
Please note: The network settings are not reset hereby! If you do not know the network settings, the
device must be connected to a controller in order to reset the settings.