17
7.7. Diagnosis
Assignment example:
Net
1
3
4
5
2
A
B
X0
X1
Mod
PoE max
PoE
L/A
PoE
L/A
PoE
L/A
PoE
L/A
PoE
L/A
IO
0.0
Power
24 V In
IO
1.0
IO
0.1
IO
1.1
L/A
L/A
24 V Out
Net
1
2
A
B
X0
X1
Mod
PoE max
PoE
L/A
PoE
L/A
IO
0.0
Power
IO
1.0
IO
0.1
IO
1.1
L/A
L/A
24 V In
24 V Out
Net
3
5
6
7
4
1
2
X0
X1
Mod
L/A
L/A
L/A
L/A
L/A
IO
0.0
Power
24 V In
IO
1.0
IO
0.1
IO
1.1
L/A
L/A
24 V Out
ZAC50EN01 ZAC50EN02 ZAC51EN01
7.7.1 LED Display EtherNet/IP
TM
Device (ZAC50EN0x)
The status displays for the communication are marked on the switch with CS and MS.
Designation
Condition
Function
Net
Off
No IP address
Green
CIP connection established
Green flashing
IP address assigned, no CIP connection
Red
IP address assigned twice
Red flashing
CIP connection interrupted
Mod
Green
Ready for operation
Green flashing
Standby
Red
Permanent error
Red flashing
Temporary error
PoE max
Red
Maximum PoE performance reached
Red flashing
PoE performance monitoring was switched off