62
EN
12.2 Overview of Receiver Parameters Configuration
The receiver’s parameters are configured by means of corresponding wiring of pins 4, 6 and 7.
Safety Mode Without
EDM
Safety Mode With
EDM
RES Without EDM
RES With EDM
Pin 4
(RES)
Jumper to pin 6
Jumper to pin 6
24 V via pushbutton
24 V via pushbutton
Pin 6
(signal
output)
–
–
Optionally to PLC or
signaling module
Optionally to PLC or
signaling module
Pin 7
(EDM)
Jumper to pin 6
24 V via closed
feedback loop
Jumper to pin 6
24 V via closed
feedback loop
12.3 Display during Normal Operation
12.3.1 Receiver
Display
Description
SIG LOW/
DIAG4
DIAG3
EDM/DIAG2
SYNC/DIAG1
ERROR
RES
OSSD OFF
OSSD ON
• Receiver and emitter are not synchronized.
SIG LOW/
DIAG4
DIAG3
EDM/DIAG2
SYNC/DIAG1
ERROR
RES
OSSD OFF
OSSD ON
• Emitter and receiver synchronized.
• Not all beams are detected.