9
3. Technical Data
Order No.
Emitter: SEMG531–SEMG542
Receiver: SEMG631–SEMG642
Emitter: SEMG512–SEMG522
Receiver: SEMG612–SEMG622
Optical Data
Range
0.2…6 m
0.25…14 m
Safety field height
250…1811 mm
326…1827 mm
Resolution
14 mm
30 mm
Aperture angle
± 2.5°
Emitter wavelength
Typically 630 nm
Coated optics
Yes
Resistance to extraneous light
10,000 lux
Electrical Data
Supply power
19.2 to 28.8 V DC (SELV, PELV power pack), it must be possible to
bridge power failures of 20 ms or more (EN 60204-1)
For US and Canada:
Device to be supplied by a certified Class 2 power supply that
complies with the requirements according NEC and CEC.
Fusing of supply voltage, inputs
Max. 2 A
Power consumption, receiver
(operating voltage = 24 V)
≤
200 mA (without load)
Power consumption, emitter
(operating voltage = 24 V)
≤
100 mA
Internal fuse
2 A
Temperature range
SFH
≤
1061 mm: −25…55° C
SFH
>
1061 mm: −5…55° C
−25…55° C
Storage temperature
−25…60° C
Relative humidity
≤
95% (non-condensing)
Vibration resistance
5 g (10 ... 55 Hz)
Shock resistance
10 g/16 ms
Signal output
Signal output
Semiconductor, PNP
Number of signal outputs
1
Signal output switching current
≤
100 mA
Signal output voltage drop
≤
2.5 V
Safety outputs
Safety outputs
Semiconductor, PNP
Number of safety outputs
2
Safety output switching current
≤
300 mA
Safety output leakage current
≤
2 mA
Voltage drop at safety output
≤
2.3 V
Max. voltage in off state
< 2 V
Max. capacitive load
≤
1 µF
Max. Inductive load
≤
2.2 mH
Summary of Contents for SEMG412