35
Long-Range Laser Distance Sensors
7.2 Condition Monitoring/Process Data
The data described in the following section can be read or written cyclically via IO-Link/process data.
7.2.1 Process Data In
Data
Meaning
Measured Value
Measured distance in mm respectively 1/10 Inch.
As the sensor cannot determine a measured value in the following error cases, substi-
tute values are read out:
No signal: 0x7FFC / 32764 mm
Object too close: 0x8008 / –32760 mm
Object too far: 0x7FF8 / 32760 mm
Scale
Scaling of the measured value to the base length unit; –3 corresponds to mm.
SSC1
Switching point 1
SSC2
Switching point 2
Warning
Collective warning in the event of one of the warning status messages (see
table
Error
Collective warning in the event of one of the error status messages (see table
Message 1
Status message 1 read out (see
Message 2
Status message 2 read out (see
Message 3
Status message 3 read out (see
Message 4
Status message 4 read out (see
7.2.2 Process Data Out
Data
Meaning
Emitted Light
Emitted light on/off
Localization
Sensor flashes for easy sensor location
Teach-In SSC1
Starts the teach-in process for SSC1
Teach-In SSC2
Starts the teach-in process for SSC2
Reset Accelera-
tion Sensor
Resets the status message for the acceleration sensor