Long-Range Laser Distance Sensors
7.1.2.3 Input Functions
The input functions are used to set the physical inputs.
Function
Possible Settings
Default
Input mode
Operating Voltage Active
The function is triggered as soon as operating voltage is applied to the
input.
Operating Voltage Inactive
The function is triggered as soon as 0 V is applied to the input or the
input is not connected.
Operating
voltage active
7.1.3 Switching Point Functions (SSC1/SSC2)
The switching point functions are used to set the two switching points, SSC1 and SSC2.
In the digital versions, SSC1 is assigned to output O1, and SSC2 is assigned to output O2.
In the analog versions, SSC1 and SSC2 are initially available via IO-Link only.
If I/O1 is configured as a switching output, SSC1 is assigned to it.
Function
Possible Settings
Default
Teach-in
Starts the teach-in process
Teach-in mode
Foreground Teach-In
Foreground
teach-in
Background Teach-In