Long-Range Laser Distance Sensors
7.1.4 Condition Monitoring Functions
7.1.4.1 Status Message Function
The sensor provides a large number of different status messages. Due to the process data structure,
four status messages can be transmitted as individual process data.
These parameters can be used to set the status messages that are transmitted via the process data.
Function
Possible Settings
Default
Message 1
See table
Warning signal
Message 2
See table
Optics dirty
Message 3
See table
Ambient light
Message 4
See table
Versions without an acceleration sensor:
Temperature too high
Versions with an acceleration sensor:
Acceleration sensor
7.1.4.2 Warning/Error Output Function
The status messages used to trigger the collective message can be defined for the warning output and the
error output respectively. The status messages are OR-linked so that the output is activated when one of the
defined status messages is activated.
Function
Possible Settings
Default
Warning output
Signal warning, optics dirty, ambient light, tem-
perature too high, temperature too low, undervolt-
age, interference in the working range
Error output
Object too close, object too far, no signal, device
error, over-temperature, short circuit