background image

FXxQ0xx

Pressure sensors with temperature measurement and IO-Link

Operating Instructions

Translation of the Original Operating Instruction

Subject to change without notice

Available as PDF version only

Version: 1.0.0

Status: 29.04.2019

www.wenglor.com

EN

Summary of Contents for FX Q0 Series

Page 1: ...ith temperature measurement and IO Link Operating Instructions Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 0 0 Status 29...

Page 2: ...autions 8 2 6 Approvals and IP Protection 8 3 Technical Data 9 3 1 Housing Dimensions 11 3 2 Wiring Diagram 12 3 3 Accessory Products 13 3 4 Layout 13 3 5 Scope of Delivery 13 4 Transport and Storage...

Page 3: ...surement and IO Link 7 Settings 23 8 IO Link 24 9 Maintenance Instructions 24 10 Returns 24 11 Proper Disposal 24 12 Appendix 25 12 1 List of Abbreviations 25 12 2 Change Index Operating Instructions...

Page 4: ...ating instructions may also be subject to change The current version can be found at www wenglor com in the product s separate download area NOTE The operating instructions must be read carefully befo...

Page 5: ...mitation of Liability The product has been developed in consideration of the current state of the art and applicable standards and guidelines Subject to change without notice A valid declaration of co...

Page 6: ...sensor is converted into an electronic signal The switching output out puts the relevant switching signal the analog output outputs the measured value optionally in 0 10 V or 4 20 mA FXxQ0xx pressure...

Page 7: ...rty damage in case of use for other than the intended purpose Use for other than the intended purpose may lead to hazardous situations Instructions regarding use for intended purpose must be observed...

Page 8: ...its service life In the event of possible changes the respectively current version of the operating instruc tions can be accessed at www wenglor com in the product s separate download area Read the o...

Page 9: ...torage temperature 25 80 C Relative humidity 100 rh EMC DIN EN 61326 2 3 Shock resistance per DIN EN 60068 2 27 30 g 11 ms Vibration resistance per DIN EN 60068 2 6 10 g 10 2000 Hz Electrical Data Sup...

Page 10: ...able to NC or NO Yes Tested by wenglor The following table specifies the tightening torques of the connector plugs and mounting options in order to assure compliant error free operation Connector Type...

Page 11: ...11 Pressure sensors with temperature measurement and IO Link 3 1 Housing Dimensions G3 4...

Page 12: ...12 Technical Data 3 2 Wiring Diagram...

Page 13: ...ide you with suitable connection technology for your product Suitable mounting technology no G3 4 920 Suitable connection technology no 2 S02 IO Link master ZAI72AN01 EFBL001 EFBL003 3 4 Layout 2 1 pl...

Page 14: ...er of the damage Then return the device making reference to damage in transit 4 2 Storage The following points must be taken into condition with regard to storage Do not store the product outdoors Sto...

Page 15: ...P69K 10 m S23 2M straight PVC 2 m S23 2MPUR straight PUR 2 m S23 5M straight PVC 5 m S23 5MPUR straight PUR 5 m S23 10M straight PVC 10 m S23 10MPUR straight PUR 10 m S29 2M angled PVC 2 m S29 5M angl...

Page 16: ...ged Comply with installation instructions CAUTION Risk of personal injury or property damage during installation Personal injury and damage to the product may occur Ensure a safe installation environm...

Page 17: ...wenglor s support department Do not operate in case of indeterminate malfunctioning The machine must be shut down if the error cannot be unequivocally clarified or reliably eliminated DANGER Risk of p...

Page 18: ...Output function Current 4 20 mA Initial value analog output 0 of the MUL Final value analog output 100 of the MUL 6 2 Function Definitions All functions are configured via the IO Link interface Refer...

Page 19: ...witching Point 1 Pression Temperature Rising Characteristic Curve Falling Characteristic Curve 6 2 2 Window Width If switching points 1 and 2 are reversed a window for actual and target value comparis...

Page 20: ...d for an additional output at the controller is eliminated and external components can be switched by the sensor e g a lamp or actuated by means of an analog control signal U I e g a valve Prerequisit...

Page 21: ...g Output e g Indicator Lamp or Remote Analog Output e g Proportional Valve Figure 1 Wiring With Remote Output Function External comp e g PLC IO Link Lamp Valve E analog digital Figure 2 Wiring PLC Ana...

Page 22: ...each 6 2 5 Filter The filter represents the number of values used by the sensor to generate a mean value for pressure mea surement The higher the filter number the longer the sensor s step response ti...

Page 23: ...ching output Pressure switching output Temperature Function output 2 switching output Pressure switching output Temperature Analog output Pressure Analog output Temperature Remote switching output Rem...

Page 24: ...uld damage the product The product must be protected against contamination during initial start up Deposits upstream from the pressure measuring cell may influence results 10 Returns Due to legal regu...

Page 25: ...MUL Measuring range upper limit 12 2 Change Index Operating Instructions Version Date Description Change 1 0 0 29 04 2019 Initial version of the operating instructions 12 3 EU Declaration of Conformit...