10
Technical Data
Mechanical Data
Setting method
IO-Link
Housing material
Stainless steel 1.4404
Media contacting materials
Stainless steel 1.4404, Seal material
(FKM/EPDM: see technical data sheet),
ceramic AI2O3 96 %
Protection
IP65*
Connector type
M12 × 1 , 4-pin
Connection cable length
max. 30 m
Process connection
G3/4"
Output Function
Configurable as PNP, NPN or push-pull
Yes
Switching output switchable to current or
voltage
Yes
Switchable to NC or NO
Yes
* Tested by wenglor
The following table specifies the tightening torques of the connector plugs and mounting options in order to
assure compliant, error-free operation:
Connector Type
Tightening Torque in Nm
Supply voltage and signal connection
M12
0,4
Process connection
G3/4 external thread
30
CAUTION!
• The pressure resistance or pressure range specified in the technical data always makes
reference to the sensor itself.
• Amongst other factors, the system’s pressure resistance is also dependent on the utilized
mounting components (adapters), and is only as high as the pressure resistance of the
weakest component.