5.  Technical Data

Order-No.

A1P05

A1P16

A2P05

A2P16

Working Range

30…50 mm

16…20 mm

30…50 mm

16…20 mm

Working Distance

40 mm

18 mm

40 mm

18 mm

Receiver Filter

GG 420

GG 420

OG 570

OG 570

Receiving Range

420…750 nm

420…750 nm

570…750 nm

570…750 nm

Switching Hysteresis

< 1 %

< 1 %

< 1 %

< 1 %

Light Source

UV-Light

UV-Light

UV-Light

UV-Light

Wave Length

380 nm

380 nm

380 nm

380 nm

Service Life (Tu = +25 °C)

100000 h

100000 h

100000 h

100000 h

Risk Group (EN 62471)

2

2

2

2

max. Ambient Light

10000 Lux

10000 Lux

10000 Lux

10000 Lux

Light Spot Diameter

5 mm

3 mm

5 mm

3 mm

Power Supply

10…30 V DC

10…30 V DC

10…30 V DC

10…30 V DC

Power Consumption

< 50 mA

< 50 mA

< 50 mA

< 50 mA

Switching Frequency

2500 Hz

2500 Hz

2500 Hz

2500 Hz

Switching Frequency

200 µs

200 µs

200 µs

200 µs

ON-/OFF-Delay

0…10 ms

0…10 ms

0…10 ms

0…10 ms

Time Delay

0…100 ms

0…100 ms

0…100 ms

0…100 ms

Temperature Drift

< 1 %

< 1 %

< 1 %

< 1%

Temperature Range

–25…60 °C

–25…60 °C

–25…60 °C

–25…60 °C

Switching Outputs

2

2

2

2

Switching Output Voltage Drop

1,5 V

1,5 V

1,5 V

1,5V

Switching Output / Switching Current

200 mA

200 mA

200 mA

200 mA

Short Circuit Protection

yes

yes

yes

yes

Reverse Polarity Protection

yes

yes

yes

yes

Lockable

yes

yes

yes

yes

Teach Mode

ZT, DT, TP

ZT, DT, TP

ZT, DT, TP

ZT, DT, TP

Interface

RS-232

RS-232

RS-232

RS-232

Baud Rate

38400 Bd

38400 Bd

38400 Bd

38400 Bd

Digital Inputs

2

2

2

2

Adjustment

Teach-In

Teach-In

Teach-In

Teach-In

Housing

Plastic

Plastic

Plastic

Plastic

Protection Mode

IP67

IP67

IP67

IP67

Connection

M12×1, 8-pin

M12×1, 8-pin

M12×1, 8-pin

M12×1, 8-pin

Protection Class

III

III

III

III

ZT: Two-Point Teach-In 

DT: Dynamic Teach-In 

TP: Key Potentiometer

Summary of Contents for A1P05

Page 1: ...A1P05 A2P05 A1P16 A2P16 Luminescence Sensors Operating Instruction SAP No 80204 Stand 05 07 2012...

Page 2: ...ation 7 7 2 Factory Default Settings 7 8 Function description 7 8 1 Switching the Output Stage to and from PNP NPN and Push Pull 7 8 2 Setting the Switching Threshold with the Teach In Function 8 8 3...

Page 3: ...ating instruction carefully before using the product Installation start up and maintenance of this product should only be carried out by trained personal Tampering with or modifying the product is not...

Page 4: ...g Frequency 2500 Hz 2500 Hz 2500 Hz 2500 Hz Switching Frequency 200 s 200 s 200 s 200 s ON OFF Delay 0 10 ms 0 10 ms 0 10 ms 0 10 ms Time Delay 0 100 ms 0 100 ms 0 100 ms 0 100 ms Temperature Drift 1...

Page 5: ...nput TxD Interface output lead T External Teach In input Minus S Shield 5 2 Housing Dimensions 1 Transmitter Diode 2 Receiver Diode 5 3 Control Panel Minus key with LED A Output switching status displ...

Page 6: ...Technology No 80 S01 Interface Cable S232W3 6 Installation Instructions During use of the Sensors applicable electrical and mechanical regulations standards and safety precautions must be adhered to...

Page 7: ...tory Default Setting On delay off Off delay off Output stage PNP Teach In mode for external Teach In Two Point Automatic intensity read out via RS 232 off Table 4 8 Function description 8 1 Switching...

Page 8: ...The LED at the plus key lights up The LED at the minus key lights up The Push Pull mode is activated Exiting the Setup Mode Set the rotary selector switch to RUN 8 2 Setting the Switching Threshold w...

Page 9: ...d upon these values This function is intended for applications where the objects to be scanned move continuously at a constant speed and cannot be brought to a standstill within the production process...

Page 10: ...quired intensity values is too small the output switching status indicator A blinks rapidly for approximately 3 seconds and switching thresholds are not updated External Dynamic Teach In Objects to be...

Page 11: ...hifted one step closer to the marking or Press and hold the plus key The switching threshold is continuously shifted closer to the marking If the LED at the plus key blinks the limit stop has been rea...

Page 12: ...se 2 blinks 50 ms Off 3 blinks pause 3 blinks 100 ms Off 4 blinks pause 4 blinks Default setting Table 3 8 6 Trigger Function at Pin 5 Set the rotary selector switch to trigger Apply the trigger signa...

Page 13: ...atus indicator blinks Release the plus key The switching status indicator continues to blink Continuous read out of intensity values is now activated Deactivating Continuous Read Out of Intensity Valu...

Page 14: ...wenglor S232W3 plug adapter Switch off the power supply Set the rotary selector switch to RS 232 Disconnect the 8 conductor connector cable S80 xx from the Sensor Connect the S232W3 plug adapter direc...

Page 15: ...communications partner the Sensor transmits the start bit ASCII 47 followed by length information and a command byte for the data bytes Transmitting Data user data After establishing a connection use...

Page 16: ...000 Transmitting Frame 020D0059 Example Transmitting Frame Length 10 in this example XOR 0001 1111 2 32H 0011 0010 Checksum 0 n 1 XOR 0010 1101 0 30H 0011 0000 As long as n Transmitting Frame Lenght 3...

Page 17: ...mit stop 1 otherwise 0 qq Checksum Adjust On and Off Delay Function Send Frame to the Sensor Response Frame from the Sensor Adjust On Delay 040A01bbqq 030MA0111 Adjust Off Delay 040A00bbqq 030MA0010 T...

Page 18: ...0351 030MO031D Table 13 Read Out Sensor Configuration The entire Sensor configuration can be read out with this command Function Send Frame to the Sensor Response Frame from the Sensor Read out config...

Page 19: ...h In dd Selected Off Delay 00 07 0 1 2 5 10 20 50 100 ms ee Selected On Delay 00 07 0 1 2 5 10 20 50 100 ms ff Output stage programming 01 PNP 02 NPN 03 Push Pull qq Checksum Query Sensor Status Funct...

Page 20: ...ulty data 030Xabbqq Table 19 If the Sensor receives faulty data for example an incorrect checksum or an unknown command it responds with an error message a Last valid command bb Last valid command set...

Page 21: ...21 Sensors for your success www wenglor com Sensors for your success www wenglor com EN...

Reviews: