19
Sensors for your success
www.wenglor.com
Sensors for your success
www.wenglor.com
EN
Change Sensor Configuration:
The entire Sensor configuration can be changed with this command.
Function
Send Frame to the Sensor
Response Frame from the Sensor
Change configuration
„/100Gaaaabbbbccddeeffqq.
/030MG0016.
Table 15
aaaa:
Upper threshold
bbbb:
Lower threshold
cc:
Teach-In mode for external Teach-In
02: Dynamic Teach-In
03: Two-Point Teach-In
dd:
Selected Off-Delay)
00-07: 0-1-2-5-10-20-50-100 ms
ee:
Selected On-Delay
00-07: 0-1-2-5-10-20-50-100 ms
ff:
Output stage programming
01: PNP
02: NPN
03: Push-Pull
qq: Checksum
Query Sensor Status:
Function
Send Frame to the Sensor
Response Frame from the Sensor
Query status
/000W48.
/0A0W000000ddeeqq.
Table 16
dd:
Off-delay value
ee:
On-delay value
qq: Checksum
Execute Sensor Reset:
Function
Send Frame to the Sensor
Response Frame from the Sensor
Execute reset
/000R4D.
/070V8a:bbccqq.
/050ROK0007C.
/030MR4D73.
Table 17
a:
Software version
bb:
Sensor group
(luminescence Sensor: OC)
cc:
Sensor type
(A1P05: 01, A1P16: 02, A2P05: 03, A2P16: 04)
qq:
Checksum