9
SELECTING A LOCATION
!
WARNING
to avoid personal
injury, use only
authorized and
trained personnel.
important:
Read all precautions on page 2 before you begin.
Select a firm level area on which to place the Showmobile for use. Face the road side toward the center
of the audience location.
Check for any possible obstructions (trees, power or light poles, overhanging wires, etc.) which might be
in the way of the roof/canopy when raised.
Be sure to park where there is access to a 110V electrical supply to operate the battery charger, for
opening and closing the roof/canopy and hydraulic stage (or access to a 220V supply if you have an
upgraded-service Showmobile).
DISCONNECTING THE TOWING VEHICLE
1. Block the Showmobile’s wheels with chocks.
2. Free the safety chain.
3. Disconnect the 12-volt electrical supply
cord which connects the brake and
running lights to the towing vehicle.
4. Disconnect the breakaway cable from
the towing vehicle’s hitch.
important:
Disconnect the breakaway
cable from the towing vehicle, rather than
pulling the pin out of the switch on the
Showmobile. If the pin is pulled from the
switch, the Showmobile brakes are
activated and will drain the battery within
two hours.
5. Pull out the release and lower the
foot plate.
6. Use the crank of the hitch jack to raise
the Showmobile coupler off the towing
vehicle hitch.
7. Move the towing vehicle away.
12-volt
Electrical
Supply
Cord
Breakaway
Cable
Hitch Jack
Crank
Summary of Contents for Showmobile
Page 30: ...30 ELECTRICAL SCHEMATIC 110 volt standard...
Page 31: ...31 ELECTRICAL SCHEMATIC CONTINUED 110 220 volt 220 volt upgrade...
Page 33: ...33 12 volt wiring diagram ELECTRICAL SCHEMATIC CONTINUED...
Page 34: ...34 HYDRAULIC SCHEMATIC manual leveling model...
Page 35: ...35 HYDRAULIC SCHEMATIC CONTINUED hydraulic leveling model...