![Wenger 5-light 30](http://html1.mh-extra.com/html/wenger/5-light-30-studio-makeup-station/5-light-30-studio-makeup-station_installation-instructions-manual_956668011.webp)
11
INSTALLATION
CONTINUED
INSTALL THE FIRST MAKEUP STATION
CONTINUED
8. level the Makeup Station as follows.
a. Place a 48" Box level across the two Counter Mounting Brackets.
b. To move the left side upward, use a 9/16-inch open end wrench and turn the left lower flange
Nut counterclockwise and the Right lower flange Nut clockwise. Turning each nut one-half turn
will lift the left edge 1/16-inch.
Note:
Always turn one nut clockwise and one nut counterclockwise the same amount to keep the
Makeup Station in the same relative position. This is important when leveling a group of Makeup
Stations.
c. To lower the left side, turn the left lower flange Nut clockwise and the Right lower flange Nut
counterclockwise.
d. When the Counter Mounting Brackets are level, tighten the two Upper flange Nuts with a 9/16-
inch open end wrench.
Box level
Counter Mounting Brackets
Mounting Bracket
Mounting Bracket
left lower flange Nut
Right lower flange Nut
Upper flange Nut