GENERATOR SAFETY WARNINGS

GENERATOR OPERATION SAFETY

1. Only use the generator for its intended purposes. Modifying or using the generator for operations for 
which it was not designed may cause hazards and personal injury.

2. Do not touch bare wires or receptacles (outlets).

3. Do not exceed the wattage capacity of the generator by plugging in more electrical devices than the unit 
can handle.

4. Allow generator to run for several minutes before connecting electrical devices.

5. Do not turn ON electrical devices until after they are connected to the generator.

6. Generators vibrate in normal use. During and after the use of the generator, inspect both the generator as 
well as extension and power supply cords for damage resulting from vibration.  

7. Do not touch HOT PARTS. This generator produces heat when running. Temperatures near exhaust can 
exceed 150º F (65º C). Allow generator to cool down after use before touching engine or areas of the gen-
erator that become hot during use.

8. Turn off all connected electrical devices before stopping the generator. 

9. Always turn generator off before refueling. Allow generator to cool for at least 2 minutes before removing 
fuel cap.  Loosen cap slowly to relieve pressure in tank.

10. Turn the engine switch to “OFF” position when the engine is not running.

11. Empty fuel tank before storing or transporting the generator. Do not store generator or gasoline near 
furnaces, water heaters, or any other appliances that produce heat or have automatic ignitions. Store the 
generator and fuel away from sparks, open flames, pilot lights, heat and other sources of ignition.

 

CAUTION: 

Misuse of this generator can damage it or shorten its lifespan.

TO MAXIMIZE THE LIFESPAN OF YOUR GENERATOR:

We recommend running your generator at least once a month for 15 to 30 minutes. Start the generator 
according to the instructions and plug a small load in to make sure the outlet is producing electricity.

If you do not run it often, it will greatly shorten the lifespan and performance of the generator.

7

Summary of Contents for 56155

Page 1: ...ormance Pay close attention to the rules for safe operation warnings and cautions If you use your tool properly and for its intended purpose you will enjoy years of safe reliable service IMPORTANT MOD...

Page 2: ...bleshooting Guide 25 Specifications 26 Wiring Diagram 27 Exploded View Parts List 28 Warranty Statement 32 SPECIFICATIONS Wattage 1350 Rated Watts 1550 Surge Watts Frequency 60Hz Rated Voltage AC 120V...

Page 3: ...NUMBER WEN 56155 DATE OF PURCHASE __________________________________________ PURCHASED FROM ___________________________________________ SERIAL NUMBER _____________________________________________ SERV...

Page 4: ...ormation regarding the generator s potential safety concerns as well as preparation operation and maintenance instructions Before operating this generator be sure to read and observe all warnings and...

Page 5: ...nutes before re moving fuel cap Loosen cap slowly to relieve pressure in tank Do not overfill fuel tank Gasoline may expand during operation Do not fill to the top of the tank Allow for expansion Alwa...

Page 6: ...asoline may expand during operation Do not fill to the very top of the tank Leave room for gasoline expansion Always check for spilled fuel before operating 3 If any part of the generator or electrica...

Page 7: ...touching engine or areas of the gen erator that become hot during use 8 Turn off all connected electrical devices before stopping the generator 9 Always turn generator off before refueling Allow gener...

Page 8: ...f any part is damaged or missing please contact our customer service at 800 232 1195 M F 8 5 CST or email us at techsupport wenproducts com KNOW YOUR GENERATOR 8 Circuit Breakers Top AC Breaker Bottom...

Page 9: ...se is 13 5 fl oz The generator is equipped with a low oil sensor and will NOT start without a sufficient amount of oil To add oil follow these steps 1 Make sure the generator is shut OFF and on a leve...

Page 10: ...el tank Fuel may expand during operation Do not fill to the top of the tank Allow for expansion Always check for spilled fuel before operating Clean up any spilled fuel before starting Empty fuel tank...

Page 11: ...on can be ensured by installing an altitude kit at altitudes higher than 2000 feet above sea level At elevations above 7000 feet the engine may experience a decrease in performance even with the prope...

Page 12: ...wered or battery backup CO alarm in the home If you start to feel sick dizzy or weak after the generator has been running move to fresh air RIGHT AWAY See a doctor You may have carbon monoxide poisoni...

Page 13: ...the recoil starter handle slowly until a slight resistance is felt Then pull quickly to start the engine Return cord gently into the machine Never allow the cord to snap back 9 If engine fails to star...

Page 14: ...connect The information should be listed on the device or in its instruction manual or you may refer to Fig 9 The wattage can be calculated using this equation Watts Volts x Amperes To calculate the...

Page 15: ...rloaded This may result in overheating or stressing the machine s components possibly leading to generator failure CONNECTING THE DEVICES CAUTION Become familiar with the markings on the panel before...

Page 16: ...mmended Fig 10 Power Cord Requirement Guide IN CASE OF OVERLOAD If your generator becomes overloaded from too much drawn wattage the circuit breaker s on your control panel will pop out and cut off po...

Page 17: ...e switch to the OFF position 3 Turn the fuel valve to the OFF horizontal position CAUTION Unplugging running devices can cause damage to the generator Never stop the engine with electrical devices con...

Page 18: ...mail techsupport wenproducts com RECOMMENDED MAINTENANCE SCHEDULE IMPORTANT GENERATOR MAINTENANCE TIPS Drain your carburetor after each use and before storage see page 19 to prevent it from clogging D...

Page 19: ...ENERATOR Recommended to drain after every use and before storage Draining the carburetor is recommended to prevent the fuel from clogging up the carburetor A clogged car buretor can prevent the genera...

Page 20: ...oil mark reaches the top of the dipstick you can see oil coming up the threads of the oil fill Do not over fill DRAINING THE OIL Change the oil according to the Recommended Maintenance Schedule in Fi...

Page 21: ...searching 56180 073 5 Saturate the element in clean engine oil and squeeze off excess oil in a clean absorbent cloth Drip the sponge like element in clean engine oil meeting the requirements specified...

Page 22: ...recommend replacing with a NGK BP7ES Torch E7TC spark plug Part No 56180 056 available for purchase at wenproducts com 4 If re using the spark plug use a wire brush to clean any dirt from around the s...

Page 23: ...fuel is drained shut OFF the fuel valve 6 Follow the instructions in DRAINING THE CARBURETOR section on page 19 to drain the carburetor 7 Remove the fuel filter cup see FUEL FILTER CUP CLEANING below...

Page 24: ...s 30 to 60 Days Drain the carburetor see page 19 Gasoline stored over 30 days can start to go bad and dam age fuel system components Add fuel stabilizer Follow the suggested portions and instructions...

Page 25: ...ting a different device Generator runs but does not sup port all electrical devices con nected Generator is overloaded Turn off and unplug all electrical devices Wait 5 minutes then press the circuit...

Page 26: ...8 lbs 25 3 kg Engine Type 4 stroke OHV single cylinder with forced air cooling system Engine Displacement 98cc Fuel Tank Capacity 1 1 US gallon 4 2 L 87 octane minimum Oil Capacity 13 5 fl oz Half Loa...

Page 27: ...27 WIRING DIAGRAM...

Page 28: ...63 56 57 58 59 54 53 52 55 43 44 45 46 47 48 49 50 51 2 3 11 12 13 14 15 16 17 18 7 64 22 23 24 25 26 28 29 27 30 31 33 22 34 35 36 24 39 38 42 37 40 32 41 21 20 19 4 10 9 8 5 6 EXPLODED VIEW PARTS L...

Page 29: ...Engine End Cover 1 31 56180 013 1 Flange Bolt M5 10 3 32 56155 032 Voltage Regulator AVR 1 No Part No Description Qty 33 56155 033 Flange Bolt M8 185 1 34 56155 034 Flange Bolt M6 110 4 35 56155 035 W...

Page 30: ...EXPLODED VIEW PARTS LIST ENGINE VIEW 30...

Page 31: ...ystem 95 56180 095 Gulp Valve Gasket 96 56180 096 Gulp Valve Connection Plate 97 56180 097 Bolt M6X16 No Part Number Description 40 56180 040 Ignition Coil Assembly 41 56180 041 Head Cover Gasket 42 5...

Page 32: ...ps resale shops or any other secondhand merchant void the warranty included with this product Contact techsupport wenproducts com or 1 800 232 1195 to make arrangements for repairs and transportation...