To prevent fuel spillage when transporting, be sure to perform the following:

1. Tighten the fuel cap.
2. Set the engine switch to OFF.
3. Drain the fuel tank if possible (see “DRAINING THE FUEL TANK” page 23).
4. Keep the generator upright. Never place the generator on its side or upside down - doing so will make 
it difficult to start.

TRANSPORTING THE GENERATOR

       

WARNING:

 Avoid direct sunlight inside a vehicle. If the generator is left in an enclosed vehicle for 

many hours, the high temperature could cause the fuel to vaporize and result in a possible explosion.

TRANSPORTATION & STORAGE

Shut off the generator and allow the unit to cool to room temperature before storing it. NEVER place any 
type of storage cover on the generator while it is still hot. Do not obstruct any ventilation openings. 

Follow the procedures below for properly storing your generator. We highly recommend running your gen-
erator once a month for 15 to 30 minutes. Plug in a small load in to ensure there is proper power output.

STORING THE GENERATOR

For Short Periods (30 to 60 Days): 

• Drain the carburetor (see page 19). 

• Gasoline stored over 30 days can start to go bad and dam-
age fuel system components. 

Add fuel stabilizer:

Follow the suggested portions and instructions of your pre-
ferred stabilizer. Run the engine for 15 to 20 minutes, allow-
ing the fuel stabilizer to mix with the gasoline and circulate 
through the carburetor, and then top off with fuel. Filling the 
fuel tank full reduces the amount of air in the tank and helps 
fight deterioration of fuel. 

For Extended Periods 

(Over 60 Days): 

• Drain the carburetor. 

• Drain the fuel tank (see “DRAINING 
THE FUEL TANK”). Never store with fuel 
in the tank for more than two months. 

       

WARNING:

 Store the generator upright in a cool and dry location, away from sources of heat, open 

flames, sparks or pilot lights.

Do not dispose of used generator or parts with your household waste. This product contains electrical or 
electronic components that should be recycled. Please take this product to your local recycling facility for 
responsible disposal to minimize its environmental impact.

Do not dispose of used oil or fuel in the trash or down a drain. Please contact your local recycling center or 
auto garage to arrange proper oil/fuel disposal. 

PRODUCT DISPOSAL

24

Summary of Contents for 56155

Page 1: ...ormance Pay close attention to the rules for safe operation warnings and cautions If you use your tool properly and for its intended purpose you will enjoy years of safe reliable service IMPORTANT MOD...

Page 2: ...bleshooting Guide 25 Specifications 26 Wiring Diagram 27 Exploded View Parts List 28 Warranty Statement 32 SPECIFICATIONS Wattage 1350 Rated Watts 1550 Surge Watts Frequency 60Hz Rated Voltage AC 120V...

Page 3: ...NUMBER WEN 56155 DATE OF PURCHASE __________________________________________ PURCHASED FROM ___________________________________________ SERIAL NUMBER _____________________________________________ SERV...

Page 4: ...ormation regarding the generator s potential safety concerns as well as preparation operation and maintenance instructions Before operating this generator be sure to read and observe all warnings and...

Page 5: ...nutes before re moving fuel cap Loosen cap slowly to relieve pressure in tank Do not overfill fuel tank Gasoline may expand during operation Do not fill to the top of the tank Allow for expansion Alwa...

Page 6: ...asoline may expand during operation Do not fill to the very top of the tank Leave room for gasoline expansion Always check for spilled fuel before operating 3 If any part of the generator or electrica...

Page 7: ...touching engine or areas of the gen erator that become hot during use 8 Turn off all connected electrical devices before stopping the generator 9 Always turn generator off before refueling Allow gener...

Page 8: ...f any part is damaged or missing please contact our customer service at 800 232 1195 M F 8 5 CST or email us at techsupport wenproducts com KNOW YOUR GENERATOR 8 Circuit Breakers Top AC Breaker Bottom...

Page 9: ...se is 13 5 fl oz The generator is equipped with a low oil sensor and will NOT start without a sufficient amount of oil To add oil follow these steps 1 Make sure the generator is shut OFF and on a leve...

Page 10: ...el tank Fuel may expand during operation Do not fill to the top of the tank Allow for expansion Always check for spilled fuel before operating Clean up any spilled fuel before starting Empty fuel tank...

Page 11: ...on can be ensured by installing an altitude kit at altitudes higher than 2000 feet above sea level At elevations above 7000 feet the engine may experience a decrease in performance even with the prope...

Page 12: ...wered or battery backup CO alarm in the home If you start to feel sick dizzy or weak after the generator has been running move to fresh air RIGHT AWAY See a doctor You may have carbon monoxide poisoni...

Page 13: ...the recoil starter handle slowly until a slight resistance is felt Then pull quickly to start the engine Return cord gently into the machine Never allow the cord to snap back 9 If engine fails to star...

Page 14: ...connect The information should be listed on the device or in its instruction manual or you may refer to Fig 9 The wattage can be calculated using this equation Watts Volts x Amperes To calculate the...

Page 15: ...rloaded This may result in overheating or stressing the machine s components possibly leading to generator failure CONNECTING THE DEVICES CAUTION Become familiar with the markings on the panel before...

Page 16: ...mmended Fig 10 Power Cord Requirement Guide IN CASE OF OVERLOAD If your generator becomes overloaded from too much drawn wattage the circuit breaker s on your control panel will pop out and cut off po...

Page 17: ...e switch to the OFF position 3 Turn the fuel valve to the OFF horizontal position CAUTION Unplugging running devices can cause damage to the generator Never stop the engine with electrical devices con...

Page 18: ...mail techsupport wenproducts com RECOMMENDED MAINTENANCE SCHEDULE IMPORTANT GENERATOR MAINTENANCE TIPS Drain your carburetor after each use and before storage see page 19 to prevent it from clogging D...

Page 19: ...ENERATOR Recommended to drain after every use and before storage Draining the carburetor is recommended to prevent the fuel from clogging up the carburetor A clogged car buretor can prevent the genera...

Page 20: ...oil mark reaches the top of the dipstick you can see oil coming up the threads of the oil fill Do not over fill DRAINING THE OIL Change the oil according to the Recommended Maintenance Schedule in Fi...

Page 21: ...searching 56180 073 5 Saturate the element in clean engine oil and squeeze off excess oil in a clean absorbent cloth Drip the sponge like element in clean engine oil meeting the requirements specified...

Page 22: ...recommend replacing with a NGK BP7ES Torch E7TC spark plug Part No 56180 056 available for purchase at wenproducts com 4 If re using the spark plug use a wire brush to clean any dirt from around the s...

Page 23: ...fuel is drained shut OFF the fuel valve 6 Follow the instructions in DRAINING THE CARBURETOR section on page 19 to drain the carburetor 7 Remove the fuel filter cup see FUEL FILTER CUP CLEANING below...

Page 24: ...s 30 to 60 Days Drain the carburetor see page 19 Gasoline stored over 30 days can start to go bad and dam age fuel system components Add fuel stabilizer Follow the suggested portions and instructions...

Page 25: ...ting a different device Generator runs but does not sup port all electrical devices con nected Generator is overloaded Turn off and unplug all electrical devices Wait 5 minutes then press the circuit...

Page 26: ...8 lbs 25 3 kg Engine Type 4 stroke OHV single cylinder with forced air cooling system Engine Displacement 98cc Fuel Tank Capacity 1 1 US gallon 4 2 L 87 octane minimum Oil Capacity 13 5 fl oz Half Loa...

Page 27: ...27 WIRING DIAGRAM...

Page 28: ...63 56 57 58 59 54 53 52 55 43 44 45 46 47 48 49 50 51 2 3 11 12 13 14 15 16 17 18 7 64 22 23 24 25 26 28 29 27 30 31 33 22 34 35 36 24 39 38 42 37 40 32 41 21 20 19 4 10 9 8 5 6 EXPLODED VIEW PARTS L...

Page 29: ...Engine End Cover 1 31 56180 013 1 Flange Bolt M5 10 3 32 56155 032 Voltage Regulator AVR 1 No Part No Description Qty 33 56155 033 Flange Bolt M8 185 1 34 56155 034 Flange Bolt M6 110 4 35 56155 035 W...

Page 30: ...EXPLODED VIEW PARTS LIST ENGINE VIEW 30...

Page 31: ...ystem 95 56180 095 Gulp Valve Gasket 96 56180 096 Gulp Valve Connection Plate 97 56180 097 Bolt M6X16 No Part Number Description 40 56180 040 Ignition Coil Assembly 41 56180 041 Head Cover Gasket 42 5...

Page 32: ...ps resale shops or any other secondhand merchant void the warranty included with this product Contact techsupport wenproducts com or 1 800 232 1195 to make arrangements for repairs and transportation...

Reviews: