Wells WV-4HSRW Operation Manual Download Page 3

WARRANTY                                                                      xi 
SPECIFICATIONS                                                             1 
FEATURES & OPERATING CONTROLS                   2 
PRECAUTIONS & GENERAL INFORMATION           6 
AGENCY LISTING INFORMATION                             7 
INSTALLATION                                                                   8 
OPERATION                                                                     12 
CLEANING INSTRUCTIONS                                        16 
MAINTENANCE SCHEDULES                                    19 
MSDS (Ansulex Low pH)                                               22 
TROUBLESHOOTING SUGGESTIONS                   24   
PARTS & SERVICE                                                        25   
CUSTOMER SERVICE DATA                                      25 

Thank You for purchasing this Wells Manufacturing Co. appliance. 

 

Proper installation, professional operation and consistent maintenance of this appliance will ensure that it 
gives you the very best performance and a long, economical service life.  

 

This manual contains the information needed to properly install this appliance, and to use and care for the 
appliance in a manner which will ensure its optimum performance. 

TABLE OF CONTENTS 

                  COOKTOP            A.C.                3ø                 1ø 
MODEL   ELEMENT           VOLTS          AMPS         AMPS     kW                  DIMENSIONS     
 

WV-4HS       4 @ 2600 Watts         240 Volts        23       22      39          45           10.7                        30.25” WIDE 

                 

(@ 240V)                                                                                                                             35.50” DEEP 

                     spiral coil                    208 Volts        20       19      34          39             8.1                        77.25” HIGH 
 
WV-4HS                                          240 Volts        27       22      43          48           11.6 
RW                
                                                        208 Volts        23       19      37          42             8.8 
 
WV-4HF       4 @ 2000 Watts         240 Volts        18       17      30          35             8.3 
                     (@ 240V) 
                     solid plate                   280 Volts        16       15      26          30             6.3 
 
WV-4HF                                          240 Volts        22       17      34          38             9.2 
RW 
                                                        208 Volts        19       15      30          34             7.0 
 
WV-4HC      4 @ 2500 Watts         240 Volts        22       21      37          43           10.3 
                     (@ 240V)                     
                     ceramic                       208 Volts        19       18      33          37             7.8 
 
WV-4HC                                         240 Volts        26       21      41          47           11.3 
RW 
                                                        208 Volts        23       22      36          41             8.5

 

SPECIFICATIONS 

INTRODUCTION 

Summary of Contents for WV-4HSRW

Page 1: ...ual is considered to be part of the appliance and is to be given to the OWNER or MANAGER of the restaurant or to the person responsible for TRAINING OPERATORS of this appliance Additional manuals are...

Page 2: ...th electrical code requirements and wiring diagrams supplied with the equipment are not covered by this warranty 4 Replacement of items subject to normal wear to include such items as knobs light bulb...

Page 3: ...ontains the information needed to properly install this appliance and to use and care for the appliance in a manner which will ensure its optimum performance TABLE OF CONTENTS COOKTOP A C 3 1 MODEL EL...

Page 4: ...9 16 18 23 9 8 a15 a11 53 12 41 44 42 43 40 a6 a31 38 18 16 22 23 VENTILATOR CONTROL PANEL see pages 4 5 COOKTOP CONTROL PANEL see pages 4 5 WARMER CONTROLS see pages 4 5 a10 70 38 Fig 1 Ventilator Se...

Page 5: ...sion media discharges here 2 places Extracts and drains most grease and moisture from the air flow Comprises the PRE FILTER FRAME and a replaceable PRE FILTER Stops larger particles of grease from rea...

Page 6: ...Features Controls Fig 3 Cooktop Section Controls Indicator Lights ROLL WARMER HUMITROL RACK DRAWER INSERT PAN COOKTOP SPIRAL HEATING ELEMENT DRIP PAN HEATING ELEMENT ROTATED ELEMENT SUPPORT SOLID PLAT...

Page 7: ...replaced RED Glows when PREFILTER and or FILTER PACK has reached the end of its service life and is too loaded to allow sufficient air flow Filter MUST be replaced Appliance is SHUT DOWN until expende...

Page 8: ...ess of this appliance is essential to good sanitation Read and follow all included cleaning instructions and schedules to ensure the safety of the food product Disconnect this appliance from electrica...

Page 9: ...e someone available who is capable of replacing it Otherwise you may experience an extended down time with consequent associated loss of business The manufacturer assumes no liability for loss of busi...

Page 10: ...IRE SUPPRESSION AGENT ANSULEX Low pH 1 5 GAL See Material Safety Data Sheet page 22 1 ea FIRE SUPPRESSION MEDIA TANK 1 ea FIRE SUPPRESSIONTANK CHARGING CARTRIDGE 1 ea GREASE BAFFLE 1 ea FILTER PACK AS...

Page 11: ...1 Incoming wiring must comply with National Electrical Code specifications All cooktop universal hood appliances ship from the factory wired 3 and include a 3 cordset For 1 operation a Remove rear lo...

Page 12: ...diately for service NOTE See page 22 for the Material Safety Data Sheet for the fire suppression agent 4 The MANUAL PULL STATION and any similar REMOTE MANUAL PULL STATION will activate the fire suppr...

Page 13: ...p indentation of the lower filter rail 3 GREASE BAFFLE If the GREASE BAFFLE is not in place the CHECK FILTERS indicator will glow To install the GREASE BAFFLE Slide the grease baffle up into the inden...

Page 14: ...2 Install the GREASE CUP on the right side of the unit directly below the grease trough HOTPLATE DRIP PAN INSTALLATION SPIRAL HEATING ELEMENTS ONLY 1 Lift rotate the elements up 2 Install a drip pan...

Page 15: ...ACE FILTER PACK lights are a warning that the indicated filter is near the end of its service life The appliance will continue to operate for a period of time after the light glows to allow continued...

Page 16: ...ntrol OFF removes power from the element LOW thru 8 are temperature settings Higher numbers indicate higher temperatures There is a continuous range of settings between LOW and HI HI is a continuous O...

Page 17: ...may form e Check the water level in the pan periodically and add water when necessary f Set the front air vent between fully closed and half open Actual setting will depend upon the type and amount o...

Page 18: ...rip pans and element supports may be washed in a sink or dishwasher Allow to air dry and reinstall Scrape burned on food debris from element using a plastic scraper or plastic scouring pad DO NOT use...

Page 19: ...y TOOLS Warm water and a mild detergent Soft clean cloth or sponge Bristle brush Container for disposal of grease CLEANING Disconnect appliance from electric power Allow to cool before cleaning Ventil...

Page 20: ...t appliance from electric power Allow to cool before cleaning FREQUENCY Monthly TOOLS Warm water and a mild detergent Soft clean cloth or sponge Plastic scouring pad plastic scraper Container for disp...

Page 21: ...total operation including FIRE DAMPER and all SAFETY INTERLOCKS b All FIRE SUPPRESSION SYSTEM actuation components including MANUAL PULL STATION and any REMOTE MANUAL PULL STATION must be inspected fo...

Page 22: ...20...

Page 23: ...21...

Page 24: ...Wt Wt CAS No CAS No ACGIH TLV ACGIH TLV Acute Toxicity Data Acute Toxicity Data None Proprietary Mixture of Organic and Inorganic Salts 48 0 50 0 Phosphoric Acid 0 2 7664 38 2 Yellow Green Fluorescent...

Page 25: ...itation persists seek medical attention Dilute by drinking large quantities of water Respiratory Protection Specify Type N A N A N A Ventilation Local Exhaust Mechanical General Protective Gloves Rubb...

Page 26: ...internal components Damaged internal components Temperature control not set Humidity control not set SUGGESTED ACTION Check reset circuit breaker Contact Authorized Ansul Distributor for repairs Obser...

Page 27: ...or factory authorized service or to order factory authorized replacement parts contact your Wells authorized service agency or call Wells Manufacturing Co 2 Erik Circle P O Box 280 Verdi NV 89439 phon...

Page 28: ...WELLS MANUFACTURING COMPANY DIVISION OF CARRIER REFRIGERATION 2 ERIK CIRCLE P O Box 280 Verdi NV 89439 Customer Service 775 345 0444 Ext 502 fax 775 345 0569 www wellsbloomfield com...