HOOD SECTION - ANSUL® FIRE DETECTION SYSTEM
12
IMPORTANT:
All servicing of the fire
detection system to be
performed by an
authorized Ansul® agent
only.
1. Cooking appliance protected by two 212ºF fusible links connected
in series. Fuse links are located in the plenum at the entry to the
ventilator fan.
2. Fire suppression system may be activated by the manual pull station
on the front of the unit, or by a remote manual pull station if installed.
3. A microswitch in the Ansul® Automan assembly allows connection to
a building fire alarm system.
SV504 SvcM
anual W
V
-4H(R
W
)
ANSU
L
P
U
LL
H
A
N
D L
E
IN
C
A S
E O
F
F IR
E
CABLE SIT S IN
GROOVE IN
PULLEY
MANUAL
PULL STATION
PULLEY
ELBOW
212ºF
212ºF
DETECTOR
IN PLENUM
MICR OSWITC H
HOOD ASSE MBLY
VIEWED FROM REAR