background image

CUSTOMER SERVICE DATA

please have this information available if calling for service

RESTAURANT _____________________________  LOCATION  _____________
INSTALLATION DATE ________________________ TECHNICIAN ___________
SERVICE COMPANY ________________________________________________
ADDRESS ___________________________ STATE ______ ZIP__________
TELEPHONE NUMBER (_____)_____-_________  

 
EQUIPMENT MODEL NO. _______________EQUIPMENT SERIAL NO. _______________

                 FUEL: (

check one

)   __ Natural Gas   __ Liquid Gas / Propane

  

28

 

DESCRIPTION 

      

 

SERVICE PART NO.

 

LEGS, 4”, METAL,  SET OF 4   

 

2A-Z0314

 

 

SCRAPER, GROOVED GRIDDLE 

 

5G-20651

PARTS & SERVICE

IMPORTANT: Use only       

factory authorized service parts 

and replacement filters.

For factory authorized
service, or to order factory  

authorized replacement parts, 

contact your Wells authorized 

service agency, or call:
 
Wells Manufacturing

10 Sunnen Dr.,

St. Louis MO 63143 USA 

Service Dept.

phone: (314) 678-6315 

fax:      (314) 781-2714

Service Parts Department 

can supply you with the name 

and telephone number of 

the WELLS  AUTHORIZED     

SERVICE AGENCY 

nearest you.

Summary of Contents for WG-2424G

Page 1: ...enance of this equipment 121 p n 2M 45324 Rev F M225 130123 OWNERS MANUAL COUNTERTOP GAS GRIDDLES MODELS WG2424G WG2436G WG3036G WG3048G Model WG2424G FOR YOUR SAFETY Do not store gasoline or other fl...

Page 2: ...the note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merc...

Page 3: ...will ensure that it gives you the very best performance and a long economical service life This manual contains the information needed to properly install this appliance and to use and care for the a...

Page 4: ...SAFETY VALVE GAS CONTROL VALVE Provides ignition pilot flame Allows fuel to burners only when pilot flame is established GREASE TROUGH Extra wide trough with radiused corners for easier cleaning Trou...

Page 5: ...d legs properly installed The technical content of this manual including any parts breakdown illustrations and or adjustment procedures is intended for use by qualified technical personnel only Any pr...

Page 6: ...before discarding packing materials Store all accessories in a convenient place for later use Thoroughly clean the appliance before use See Cleaning Instructions page 12 SETUP Supplied legs must be pr...

Page 7: ...ust conform to local codes or in the absence of such codes with the current edition of National Fuel Gas Code ANSI Z223 1 For use in the State of Massachusetts this appliance must be installed in comp...

Page 8: ...he gas pressure regulator It is the responsibility of the gas piping installer to identify the code requirement for a shut off valve Shut off valves moisture trap and all associated piping must be sup...

Page 9: ...ve any adapters and to re plug and leak check the port before returning the griddle to service Leak testing should be performed using a water soap solution DO NOT USE FLAME TO CHECK FOR GAS LEAKS GAS...

Page 10: ...removing the pilot adjusting screw cover notice the fiber washer and turning the adjusting screw until the pilot flame covers 3 8 to 1 2 tall section of the thermocouple This will ensure that the ther...

Page 11: ...he griddle surface with a clean damp cloth until all oil is removed e For new griddles repeat this procedure 2 3 times until the griddle has a slick clean surface CHROME PLATED GRIDDLES Because the mi...

Page 12: ...be lit before the associated main burner can be operated This operation requires a LONG match or fireplace lighter Set all temperature control knobs and gas safety valve control knobs to the OFF posi...

Page 13: ...th your own menu items will be your best guide to achieving the best food product OPERATION USING THE GRIDDLE Check the chart below for recommended cooking temperatures Turn temperature control knob t...

Page 14: ...Clean the griddle surface down to bright metal Wipe off any remaining powder residue b For grooved surface griddles use the supplied contoured scraper to scrape food waste Clean the griddle surface do...

Page 15: ...g all cooking waste from grease trough into the grease drawer take the grease drawer to kitchen cleaning area and properly dispose of all waste a Clean drawer with hot water and a mild detergent b Dry...

Page 16: ...Remove burner and dry thoroughly Damaged temperature control burner or other internal component Contact Authorized Wells Service Agency for repairs Burner not hot enough Temperature control not set A...

Page 17: ...5324 Owners Manual Countertop Gas Griddles WIRING DIAGRAM 15 NOTE Shown is the wiring diagram for a single burner section Each burner section is wired identically TH TP TP TH GAS VALVE THERMOSTAT THER...

Page 18: ...2M 45324 Owners Manual Countertop Gas Griddles WG2424G CABINET COMPONENTS Model WG2424G Countertop Gas Griddle Cabinet Components PL121 IL1836 Rev F 4 25 14 1 2 3 4 15 14 13 10 5 38 6 8 Namplate locat...

Page 19: ...Countertop Gas Griddles 19 EXPLODED VIEW PARTS LIST WG2424G FUEL SYSTEM COMPONENTS Model WG2424G Countertop Gas Griddle Fuel System Components PL121 IL1837 Rev D 4 13 12 18 19 20 35 34 21 22 23 24 25...

Page 20: ...DEFLECTOR HEAT FR WG2424 17 G7 39331 1 CHUTE ASSY GREASE GAS GRI 18 2J 39284 1 REGULATOR ADJ GAS LP 2J 39007 REGULATOR ADJ GAS NAT 2J 306629 RGLTR GAS CONVRT 5 10 WC LP or NAT 19 2C 40680 2 NUT 10 32...

Page 21: ...8528 ASSEMBLY 59039 65951 59331 2C 35485 G7 Z18307 2436PS model 2C 35485 G7 45292 G7 45278 2C 33453 59173 2R 38668 G7 Z12047 2M 300534 2C 33935 2A Z0314 G7 45399 Lower G7 45400 Upper G7 WL0596 IL1831...

Page 22: ...aces 3 places 1 2 3 3 places OFF 4 5 0 400 3 5 0 3 0 0 250 2 0 0 2J 39007 2J 39284 NAT LP 2F 45303 2C 40680 2C 31718 WS 65361 3 places 2R 45321 2J 45308 pilot plus NAT orifice 2A 45352 LP orifice only...

Page 23: ...es G7 39331 G7 45269 2C 35485 G7 45292 G7 45278 2C 33453 WS 59173 G7 Z12047 2R 38668 2M 300534 2C 33935 G7 45297 G7 45399 G7 45288 2H 39039 G7 45952 2C 35485 IL1838 Rev C 7 31 15 Model WG3036G Namplat...

Page 24: ...ces 3 places 3 places 3 places ADJUSTABLE REGULATOR 2J 39007 NAT 2J 39284 LP REGULATOR CONVERTIBLE FOR LP OR NAT 2J 306629 2A 45318 2A 45314 2P 39245 2A 45315 2A 45316 2A 45317 WS 65307 2K 45357 2C 31...

Page 25: ...binet Components PL121 IL1840 Rev C 9 02 14 Namplate location after 4 2014 4 places 4 places 2 places 2H 39039 G7 45952 2C 35485 G7 39331 2C 35485 G7 45375 G7 45278 2C 33453 WS 59173 G7 Z12047 2R 3866...

Page 26: ...ABLE REGULATOR 2J 39007 NAT 2J 39007 NAT REGULATOR CONVERTIBLE FOR LP OR NAT 2J 306629 2A 45318 2A 45314 2A 45315 2A 45317 2A 45316 2A 45319 2P 39245 2F 45302 DD 60680 2K Z13246 WS 65361 2C 31718 2K 4...

Page 27: ...NOTES 27...

Page 28: ...SERIAL NO _______________ FUEL check one __ Natural Gas __ Liquid Gas Propane 28 DESCRIPTION SERVICE PART NO LEGS 4 METAL SET OF 4 2A Z0314 SCRAPER GROOVED GRIDDLE 5G 20651 PARTS SERVICE IMPORTANT Use...

Page 29: ...n 2M 45324 Rev F M225 130123 MANUEL DE L UTILISATEUR PLAQUES DE COMPTOIR GAZ MOD LES WG2424G WG2436G WG3036G WG3048G Mod le WG2424G POUR VOTRE S CURIT Ne conservez pas d essence ou tout autre liquide...

Page 30: ...pareil per mettront ce dernier de vous offrir un rendement optimal et une dur e de vie prolong e et conomique Ce manuel contient les informations n cessaires pour installer ad quatement cet appareil e...

Page 31: ...est une indication du r glage de la temp rature La temp rature actuelle la surface de la plaque variera selon le type et la temp rature initiale du produit et autres variables SOUPAPE DE S RET POUR L...

Page 32: ...technique de ce manuel y compris les illustrations clat es des pi ces et ou des proc dures de r glage est destin une utilisation par du personnel technique qualifi uniquement Toute proc dure exigeant...

Page 33: ...s accessoires un endroit commode pour une utilisation ult rieure Nettoyer rigoureusement l appareil avant de l utiliser Se reporter aux Instructions de nettoyage la page 12 INSTALLATION Les pattes fou...

Page 34: ...ux la version en vigueur de la norme ANSI Z223 1 Pour utilisation dans l tat du Massachusetts cet appareil doit tre install conform ment au Code CMR 248 Massachusetts Fuel Gas and Plumbing L installat...

Page 35: ...r les exigences du code relatives une soupape d arr t Les soupapes d arr t les purgeurs de condensat et tous les conduits connexes doivent tre fournis par l installateur des conduits de gaz DANGER RIS...

Page 36: ...proc der une d tection de fuite de l orifice avant de remettre la plaque en fonction La v rification de fuite doit tre effectu e avec une solution d eau et de savon NE PAS utiliser une flamme pour d t...

Page 37: ...t e au niveau de la soupape de s ret en enlevant le couvercle de la vis de r glage de la veilleuse remarquer la rondelle en fibre et en tournant la vis de r glage jusqu ce que la flamme de la veilleus...

Page 38: ...un linge humide propre jusqu l limination de toute l huile E Pour les nouvelles plaques r p ter cette proc dure 2 3 fois jusqu l apparition d une surface lisse et propre sur la plaque PLAQUES CHROM ES...

Page 39: ...eilleuse qui doit tre allum e avant que le br leur principal connexe puisse tre mis en fonction Cette proc dure requiert l utilisation d une allumette LONGUE ou d un briquet foyer R gler tous les bout...

Page 40: ...ser les meilleurs aliments FONCTIONNEMENT UTILISATION DE LA PLAQUE Consulter le tableau ci dessous pour les temp ratures de cuisson recommand es Tourner le bouton de r glage de la temp rature jusqu la...

Page 41: ...racler les d chets alimentaires Nettoyer la surface de la plaque jusqu l obtention d un m tal brillant Essuyer tout r sidu de poudre restant b Pour les plaques rainur es utiliser le racloir profil fou...

Page 42: ...ires du passage d coulement vers le tiroir graisse transporter ce dernier vers la zone de nettoyage de la cuisine et jeter tous les d chets de fa on appropri e a Nettoyer le tiroir avec de l eau chaud...

Page 43: ...r et s cher fond Dommage au bouton de r glage de la temp rature au br leur ou un autre composant interne Contacter un centre de d pannage autoris de Wells pour proc der aux r parations Le br leur n es...

Page 44: ......

Page 45: ......

Page 46: ...WELLS MANUFACTURING 10 Sunnen Dr St Louis MO 63143 telephone 314 678 6314 fax 314 781 2714 www wellsbloomfield com...

Reviews: