MAINTENANCE INSTRUCTIONS

12

ADJUSTMENTS AND LUBRICATION

PRECAUTIONS:   

Turn control knob to OFF.  Unplug warmer

 

 

Allow drawers to cool before proceeding.

 

 

Remove drawer pans and Humitrol racks

FREQUENCY: 

Minimum -  Every 2 weeks recommended.

TOOLS:   

Screwdrivers, Phillips (+) and flat blade (-).

 

 

Nut drivers, 3/8” and 7/16”. 

  

 

 

 

Food-grade lubricant.

1.  Check slides on cabinet and drawers for cleanliness.
2.  Check all rollers on cabinet and drawers for cleanliness and        

tightness.  Lubricate.

3.  Check cabinet drawer stops for operation.  Stops must “snap” 

down   positively.  Clean and adjust as required.

4.  Check cabinet heating element fasteners for tightness.
5.  Check all cabinet drawer catches for tightness and operation.        

Lubricate.  Be certain roller is “out” before attempting to install  

drawer.

6.  Check temperature sensor.  Sensor must be securely mounted in  

the appropriate holder. 

7.  Check drawer faceplate and handle fasteners for tightness.
8.  Check drawer catch clip for tightness.
9.  Examine condition of gasket.  Arrange repairs for torn or  

damaged  drawer gaskets.

10. Reinstall drawers and check for proper operation.

Procedure is complete.

047 p/n 307538  OpM Free-Standing Drawer W

armer w/ Solid State Control

1

6

5

4

2

3

1

1

2

2

8

9

3

7

IL1936, Rev. -, M048

Summary of Contents for RWN-1 thru RWN-3 Narrow

Page 1: ...TORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if yo...

Page 2: ...e note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merchan...

Page 3: ...nsistent maintenance of this appliance will ensure that it gives you the very best performance and a long economical service life This manual contains the information needed to properly install this a...

Page 4: ...DRAWER STOP DRAWER ROLLER DRAWER ROLLERS HEATING ELEMENT ROLLER CATCH DRAWER CATCH DRAWER GASKET HUMITROL RACK DRAWER INSERT PAN AIR VENT CONTROL ADJUSTABLE LEG POWER CORD POWER SWITCH CONTROL MODULE...

Page 5: ...own illustrations and or adjustment procedures is intended for use by qualified technical personnel Any procedure which requires the use of tools must be performed by a qualified technician This manua...

Page 6: ...ed to level the appliance All four legs must be adjusted to firmly contact the floor in order to prevent tipping If drawers were removed during installation install drawer s in unit a Check the roller...

Page 7: ...y authorized technician DO NOT open any access panel which requires the use of tools Failure to follow this warning can result in severe electrical shock CAUTION RISK OF DAMAGE DO NOT connect or energ...

Page 8: ...arrow to decrease F or C Indicator Lit to indicate if unit is configured for degrees Fahrenheit or degrees Celsius Load Indicator Lit when output is energized PROCESS IL1932 Rev M048 F C LOAD CHANGE...

Page 9: ...OAD indicator glows when heating element is energized Press PROCESS key to view actual temperature inside the warmer cavity OPERATION continued 7 PROCESS F C LOAD is displayed IL1934 Rev M048 SET SETP...

Page 10: ...e steam table pans b Place a small amount of water in drawer pan Place the steam table pans in the drawer pan c Check the water level in the pan periodically and add water when necessary 3 Dry heat a...

Page 11: ...ation warmer frequently during use DO Use a Humitrol Rack or Insets to hold food for moist operation 3 DO Use warm water to add to the pan during moist operation DO NOT Put ice into a warmer pan Ice i...

Page 12: ...them in warmer 3 Sweep crumbs and other debris from warmer cavity 4 Clean the outside of the unit by wiping with a clean cloth or sponge warm water and mild detergent Dry with a clean cloth then wipe...

Page 13: ...er in pan evaporated or low Add water to pan Food gets soggy Food contacting water Use a Humitrol Rack Water level too high Water should be no more than 1 2 deep Humidity control air vent not set OPEN...

Page 14: ...t and drawers for cleanliness and tightness Lubricate 3 Check cabinet drawer stops for operation Stops must snap down positively Clean and adjust as required 4 Check cabinet heating element fasteners...

Page 15: ...ON DATE ________________________ TECHNICIAN ___________ SERVICE COMPANY ________________________________________________ ADDRESS ___________________________ STATE ______ ZIP__________ TELEPHONE NUMBER...

Page 16: ...WELLS MANUFACTURING 10 Sunnen Dr St Louis MO 63143 telephone 314 678 6314 fax 314 781 2714 www wellsbloomfield com...

Reviews: