background image

ELECTRICAL INSTALLATION

 

 

1.    Refer to the nameplate.  Verify the electrical service power.       
       Voltage and phase must match the nameplate specifications.     
       Wiring the unit to the wrong voltage can  severely damage the unit 
       or cause noticeably decreased performance.   

 

2.    Available electrical service amperage must meet or exceed the  
       specifications listed on the specification sheet provided with the 
       unit.   
       a.     Units are equipped with a three-prong (grounding) plug for your 
               protection against electric shock.  This must be plugged into a 
               properly grounded matching  receptacle. 
       b.     RCP-100 thru -600 and RCP-7100 thru -7400 are equipped   
               with a NEMA 5-15P plug and require a matching NEMA 5-15R 
               receptacle. 
 
 
 
 
 
 
 
 
       c.     RCP-7500 and -7600 are equipped with a NEMA 5-20P plug 
               and require a matching NEMA 5-20R receptacle. 
 
 
 
 
 
 
 
 

PLUMBING INSTALLATION 

 

1.    

Plumb connections must be made in compliance with all  Federal, 

       State and Local Plumbing Codes and Ordinances.

 

 

       IMPORTANT:  

All drain plumbing installations must be performed 

       by a qualified plumber. 

 

2.    Install 1" drain valve (provided by others) on unit drain.  Plumb to 
       an appropriate waste as required by local plumbing and sanitation  
       ordinances. 

 

 

INSTALLATION (continued) 

WARNING: 

Electric 
Shock hazard 

 

All servicing requiring 
access to non-insulated    
electrical components must 
be performed by a factory    
authorized technician. 
DO NOT open any access 
panel which requires the use 
of tools.  Failure to 
follow this warning can 
result in severe electrical 
shock.

 

 

CAUTION: 

Risk of 
Damage 

 

DO NOT connect or energize 
this appliance until all        
installation instructions are 
read and followed.  Damage 
to the  appliance will result if 
these instructions are not  
followed. 

 

CAUTION: 

Electrical Shock   
Hazard 

 

Cord -connected units are 
equipped with a three-prong  
plug for your protection 
against electric shock.  Never 
cut the large round prong 
from the plug, or twist a blade 
to fit an existing receptacle. 
 

 

IMPORTANT: 

Damage due to being 
connected to the wrong     
voltage or phase is NOT    
covered by warranty.

 

Summary of Contents for RCP-100

Page 1: ...ELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if you have any questions concerning installation operation or maintenance of this equipment 405 p n 305101 Rev M405 022103 cps Model RCP 300 OPERATION MANUAL RCP Series DROP IN REFRIGERATED COLD PANS MODELS RCP 100 RCP 7100 RCP 200 RCP 7200 RCP 300 RCP 7300 RCP 400 RCP 7...

Page 2: ...cordance with electrical code requirements and wiring diagrams supplied with the equipment are not covered by this warranty 4 Replacement of items subject to normal wear to include such items as knobs light bulbs and normal maintenance functions including adjustments of thermostats adjustment of micro switches and replacement of fuses and indicating lights are not covered by warranty 5 Damage to e...

Page 3: ... and a long economical service life This manual contains the information needed to properly install this appliance and to use and care for the appliance in a manner which will ensure its optimum performance TABLE OF CONTENTS INTRODUCTION 1 ELECTRICAL REFRIGERATION SPECIFICATIONS AMPS 115VAC 1ø REFRIGERANT PRESSURE psig POWER SUPPLY CORD TOTAL MCA MFS LRA TYPE AMT HIGH LOW RCP 100 RCP 200 RCP 300 R...

Page 4: ...FEATURES OPERATING CONTROLS 2 NOTE This is a general arrangement drawing only Actual component positions may vary between units ...

Page 5: ... technical personnel Any procedure which requires the use of tools must be performed by a qualified technician This manual is considered to be a permanent part of the appliance This manual and all supplied instructions diagrams schematics parts breakdown illustrations notices and labels must remain with the appliance if it is sold or moved to another location This appliance is made in the USA Unle...

Page 6: ...derstand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all accessories in a convenient place for later use RCP units must remain upright at all times shipping and installation to prevent damage to the condensing unit If the unit is accidentally tipped allow unit to sit upright for at least 24 hours b...

Page 7: ...lumbing Codes and Ordinances IMPORTANT All drain plumbing installations must be performed by a qualified plumber 2 Install 1 drain valve provided by others on unit drain Plumb to an appropriate waste as required by local plumbing and sanitation ordinances INSTALLATION continued WARNING Electric Shock hazard All servicing requiring access to non insulated electrical components must be performed by ...

Page 8: ...SWITCH located on condensing unit ON Allow unit to run for approximately 30 minutes to reach operating temperature 2 Add necessary adapter bars or adapter plates Adapter bars provided with the unit are designed to hold 12 x 20 food pans up to 6 deep For NSF 7 operation use 12 x 20 x 4 deep pans on the lower pan rail supports 3 Install appropriate food pans or insets Place pre chilled product in fo...

Page 9: ...rs pan rail and drain screen Wipe interior of tank using a clean cloth or sponge and mild detergent 2 Use a plastic scouring pad to remove any mineral deposits 3 Rinse tank thoroughly with a vinegar and water solution to neutralize all detergent cleanser residue 4 Clean pan adapter bars and pan rail with a cloth or sponge dampened in clean water Dry thoroughly then reinstall 5 Check drain screen i...

Page 10: ...ically top to bottom Collect and discard all lint and debris gathered from this operation IMPORTANT The fins of the condenser coil are delicate and easily damaged Use care to brush only in a vertical motion to avoid damaging the coil fins 4 Wipe the fan blades to remove accumulated lint 5 Reconnect to electrical power Test for proper operation CAUTION Personal Injury Hazard Disconnect appliance fr...

Page 11: ...aces b Stainless steel pads may be used ONLY IF the scrubbing motion is in the direction of the visible grain DO NOT use a circular motion c In the absence of visible grain use only soft cloth or plastic pads Scrub only in a linear motion along the longest axis of the equipment 4 Use only non chloride and non ammonia cleansers a DO NOT use any cleanser listed as chlorinated b DO NOT use any cleans...

Page 12: ...degrees Fahrenheit or C degrees Celsius Press either up arrow Ï or down arrow Ð to toggle between F and C designation 2 Press SET again to access the setpoint The LCD will display the current setpoint and the S1 annunciator will blink off and on to indicate that control is in the setpoint mode Press either up arrow Ï to increase the setpoint or down arrow Ð to decrease the setpoint to the desired ...

Page 13: ...t the differential settings of the refrigeration system Field adjustments of the differential settings must be made by qualified refrigeration personnel only Unauthorized adjustment of the differential settings will void the warranty Press either up arrow Ï to increase the differential or down arrow Ð to decrease the differential to the desired setting Factory differential is 3ºF 4 Press the SET k...

Page 14: ...Stir thick food frequently Setpoint too high Set to desired temperature Condenser cooling louvers or coil plugged Clean condenser louvers and or coil Refrigerant level low Contact Authorized Wells Service Agency for repairs Internal damage Contact Authorized Wells Service Agency for repairs NSF 7 operation using wrong rail position For holding critical foods pan rails must be assembled using the l...

Page 15: ...arts and replacement filters For factory authorized service or to order factory authorized replacement parts contact your Wells authorized service agency or call Wells Manufacturing Co 2 Erik Circle P O Box 280 Verdi NV 89439 phone 775 689 5700 fax 888 492 2783 Service Parts Dept Service Parts Department can supply you with the name and telephone number of the WELLS AUTHORIZED SERVICE AGENCY neare...

Page 16: ......

Reviews:

Related manuals for RCP-100