INSTALLATION 

NOTE:

  DO NOT discard 

the carton or other packing 
materials until you have 
inspected the appliance for 
hidden damage and tested it 
for proper operation. 
Refer to 

SHIPPING DAMAGE 

CLAIM PROCEDURE 

on the 

inside front cover of this 
manual. 

 

WARNING: 

Risk of  
personal injury 

 

Installation procedures must 
be performed by a qualified 
technician with full knowledge 
of all applicable electrical and 
plumbing codes.  Failure can 
result in personal injury and 
property damage. 
 

IMPORTANT: 

Unit must remain in an upright 
position  during installation to 
prevent damage to the          
refrigeration system. 
 

IMPORTANT: 

Refrigeration system is air 
cooled.  Recommend louvered 
grills or equivalent openings 
front and rear, each with a 
minimum size of twice the  
surface area of the condenser, 
to provide adequate air            
circulation. 
 

IMPORTANT: 

Access is required for the    
operation of the drain valve 
and for maintenance of the 
refrigeration unit.  Provide 
adequate access to the drain 
valve and refrigeration unit. 
 

IMPORTANT: 

Unit flange must be sealed to 
the counter top.  Damage 
caused by leaks due to        
improper installation is NOT 
covered by warranty.  

 

UNPACKING & INSPECTION 

 

Carefully remove the appliance from the carton.  Remove all  
protective plastic film, packing materials and accessories from the 
Appliance before connecting electrical power or otherwise performing 
any installation procedure. 

 

Carefully read all instructions in this manual and the 

Installation 

Instruction Sheet

 packed with the appliance before starting any 

installation. 

 

Read and understand all labels and diagrams attached to the 
appliance. 

 

Carefully account for all components and accessories before 
discarding packing materials.  Store all accessories in a convenient 
place for later use. 

 

RCP units must remain upright at all times (shipping and installation) to 
prevent damage to the condensing unit.  If the unit is accidentally 
tipped, allow unit to sit upright for at least 24 hours before connecting to 
electric power. 

 

COMPONENTS 

 

1 ea.             PAN RAIL 
1 - 5 ea.       PAN ADAPTER BAR(S) ( qty differs with unit) 
 

PREPARATION 

 

BEFORE INSTALLING, refer to the 

Installation Instructions

 provided 

with the unit.  Cutout dimensions and other pertinent information is    
detailed on the 

Installation Instructions

 

Provide at least 1" clearance around the condensing unit chassis. 

 

Countertop must be flat and level before the unit is installed.    After 
cutout is made, add stiffeners or bottom braces to counter as required 
to support unit weight. 

 

IMPORTANT: 

Refrigeration system is air cooled.  Recommend louvered grills or 
equivalent openings front and rear, each with a minimum size of 
twice the surface area of the condenser, to  provide adequate air 
circulation. 

 

NOTE:  

The condenser fan is provided with a fan guard.  DO NOT     

remove the condenser fan guard. 

 

Provide louvered grills and service access below control panel. Provide 
access to the POWER SWITCH and TEMPERATURE CONTROL 
UNIT located at the front of the condenser. 

 

Verify that proper type and quantity sealants are applied to the           
underside of the top flange prior to setting the unit into the cutout. 

 

After installation, apply a thin bead of food-grade silicone sealant 
around the flange to seal it to the counter. 

 

Avoid storing flammable or combustible materials in, on or near the   
appliance.

 

Summary of Contents for RCP-100

Page 1: ...ELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if you have any questions concerning installation operation or maintenance of this equipment 405 p n 305101 Rev M405 022103 cps Model RCP 300 OPERATION MANUAL RCP Series DROP IN REFRIGERATED COLD PANS MODELS RCP 100 RCP 7100 RCP 200 RCP 7200 RCP 300 RCP 7300 RCP 400 RCP 7...

Page 2: ...cordance with electrical code requirements and wiring diagrams supplied with the equipment are not covered by this warranty 4 Replacement of items subject to normal wear to include such items as knobs light bulbs and normal maintenance functions including adjustments of thermostats adjustment of micro switches and replacement of fuses and indicating lights are not covered by warranty 5 Damage to e...

Page 3: ... and a long economical service life This manual contains the information needed to properly install this appliance and to use and care for the appliance in a manner which will ensure its optimum performance TABLE OF CONTENTS INTRODUCTION 1 ELECTRICAL REFRIGERATION SPECIFICATIONS AMPS 115VAC 1ø REFRIGERANT PRESSURE psig POWER SUPPLY CORD TOTAL MCA MFS LRA TYPE AMT HIGH LOW RCP 100 RCP 200 RCP 300 R...

Page 4: ...FEATURES OPERATING CONTROLS 2 NOTE This is a general arrangement drawing only Actual component positions may vary between units ...

Page 5: ... technical personnel Any procedure which requires the use of tools must be performed by a qualified technician This manual is considered to be a permanent part of the appliance This manual and all supplied instructions diagrams schematics parts breakdown illustrations notices and labels must remain with the appliance if it is sold or moved to another location This appliance is made in the USA Unle...

Page 6: ...derstand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all accessories in a convenient place for later use RCP units must remain upright at all times shipping and installation to prevent damage to the condensing unit If the unit is accidentally tipped allow unit to sit upright for at least 24 hours b...

Page 7: ...lumbing Codes and Ordinances IMPORTANT All drain plumbing installations must be performed by a qualified plumber 2 Install 1 drain valve provided by others on unit drain Plumb to an appropriate waste as required by local plumbing and sanitation ordinances INSTALLATION continued WARNING Electric Shock hazard All servicing requiring access to non insulated electrical components must be performed by ...

Page 8: ...SWITCH located on condensing unit ON Allow unit to run for approximately 30 minutes to reach operating temperature 2 Add necessary adapter bars or adapter plates Adapter bars provided with the unit are designed to hold 12 x 20 food pans up to 6 deep For NSF 7 operation use 12 x 20 x 4 deep pans on the lower pan rail supports 3 Install appropriate food pans or insets Place pre chilled product in fo...

Page 9: ...rs pan rail and drain screen Wipe interior of tank using a clean cloth or sponge and mild detergent 2 Use a plastic scouring pad to remove any mineral deposits 3 Rinse tank thoroughly with a vinegar and water solution to neutralize all detergent cleanser residue 4 Clean pan adapter bars and pan rail with a cloth or sponge dampened in clean water Dry thoroughly then reinstall 5 Check drain screen i...

Page 10: ...ically top to bottom Collect and discard all lint and debris gathered from this operation IMPORTANT The fins of the condenser coil are delicate and easily damaged Use care to brush only in a vertical motion to avoid damaging the coil fins 4 Wipe the fan blades to remove accumulated lint 5 Reconnect to electrical power Test for proper operation CAUTION Personal Injury Hazard Disconnect appliance fr...

Page 11: ...aces b Stainless steel pads may be used ONLY IF the scrubbing motion is in the direction of the visible grain DO NOT use a circular motion c In the absence of visible grain use only soft cloth or plastic pads Scrub only in a linear motion along the longest axis of the equipment 4 Use only non chloride and non ammonia cleansers a DO NOT use any cleanser listed as chlorinated b DO NOT use any cleans...

Page 12: ...degrees Fahrenheit or C degrees Celsius Press either up arrow Ï or down arrow Ð to toggle between F and C designation 2 Press SET again to access the setpoint The LCD will display the current setpoint and the S1 annunciator will blink off and on to indicate that control is in the setpoint mode Press either up arrow Ï to increase the setpoint or down arrow Ð to decrease the setpoint to the desired ...

Page 13: ...t the differential settings of the refrigeration system Field adjustments of the differential settings must be made by qualified refrigeration personnel only Unauthorized adjustment of the differential settings will void the warranty Press either up arrow Ï to increase the differential or down arrow Ð to decrease the differential to the desired setting Factory differential is 3ºF 4 Press the SET k...

Page 14: ...Stir thick food frequently Setpoint too high Set to desired temperature Condenser cooling louvers or coil plugged Clean condenser louvers and or coil Refrigerant level low Contact Authorized Wells Service Agency for repairs Internal damage Contact Authorized Wells Service Agency for repairs NSF 7 operation using wrong rail position For holding critical foods pan rails must be assembled using the l...

Page 15: ...arts and replacement filters For factory authorized service or to order factory authorized replacement parts contact your Wells authorized service agency or call Wells Manufacturing Co 2 Erik Circle P O Box 280 Verdi NV 89439 phone 775 689 5700 fax 888 492 2783 Service Parts Dept Service Parts Department can supply you with the name and telephone number of the WELLS AUTHORIZED SERVICE AGENCY neare...

Page 16: ......

Reviews:

Related manuals for RCP-100