background image

MAINTENANCE INSTRUCTIONS

7

CARE OF STAINLESS STEEL

Stainless steel is a marvelous material:  strong, lustrous and low maintenance. With 

a minimum of care, it will normally retain its beauty and durability for the life of  the     

equipment.  In some applications, however, special care is required in order to maintain 

stainless steel’s special properties.

External components, such as cabinets and control panels, are finished with a grain  

pattern. This pleasing finish is best maintained by cleaning with a non-abrasive      

cleanser applied with a soft cloth.  Rub only in the direction of the grain.  In the absence 

of visible grain, rub only along the longest axis of the appliance.

Restore stainless steel’s luster by applying a polish specifically made for stainless steel.  

Spray on, wipe off with a soft cloth, rubbing in the direction of the grain.

Never use metal implements, wire brushes, abrasive scratch pads or steel wool to 

clean stainless steel.

Warmer pans, insets and other vessels are subject to a harsher environment.  Wells 

Manufacturing uses an very high quality stainless steel (#304DDQ) for our food warmer 

pans.  Even the highest quality stainless steel, however, is mostly iron, and will rust, pit 

and corrode under the following conditions:

Poor Water Quality:  

Hard water (water with a high content of dissolved miner-

als) will leave mineral deposits when allowed to dry.  Calcium (lime) can buildup on 

heated surfaces, even under water.  If left unattended, hard water spots and lime 

buildup can lead to rusting, corrosion and pitting.

Contact with Chlorides:  

Chlorides (specific compounds of chlorine) are found in 

food, table salt and many cleansers.  Chlorides can attack the surface of stainless 

steel, resulting in corrosion and pitting.

 

keep your stainless steel warmers clean and free from calcium buildup.

 

Use alkaline, alkaline chlorinated or non-chloride cleanser.  

 

Use citric acid-based cleaners to remove calcium deposits.

For additional information, please read the NAFEM Stainless Steel Equipment and 

Cleaning Guide.  Contact NAFEM at :

 

North American Association of Food Equipment Manufacturers

 

401 N. Michigan Avenue

 

Chicago, Illinois  60611-4267

 

(312) 644-6610

M01

1C.15 2M-308026 Owners Manual for Built-In Five-W

ell 

Auto-Fill Modual W

armers

M01

1C.15 2M-308026 Owners Manual for Built-In Five-W

ell 

Auto-Fill Modual W

armers

Summary of Contents for MOD-500TDMAF

Page 1: ...is appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if you have any...

Page 2: ...FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merchandise is unpacked notify the transportation company or carrier immediat...

Page 3: ...appliance will ensure that it gives you the very best performance and a long economical service life This manual contains the information needed to properly install this appliance and to use and care...

Page 4: ...osition is marked NOTE The dial position is an indication of the temperature setting Actual temperature will vary depending upon the type of product and food consistency B MOUNTING 1 Top mounted built...

Page 5: ...ns must be read and understood by all persons using or installing this appliance Cleanliness of this appliance is essential to good sanitation Read and follow all included cleaning instructions and sc...

Page 6: ...installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all accessories in a c...

Page 7: ...Code PLUMBING INSTALLATION For use in the State of Massachusetts this appliance must be installed in compliance with Massachusetts Fuel Gas and Plumbing Code CMR 248 1 IMPORTANT All plumbing installa...

Page 8: ...2 qt 4qt 7 qt and 11 qt sizes with lids and adapter tops b For dry operation a 6 deep pan or inset is recommended 2 Turn temperature control to HI or highest temperature setting 3 Allow warmer to pre...

Page 9: ...ells Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless steel however is mostly iron and will rust pit and corrode under the fol...

Page 10: ...nspect warmer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating element causing a potential fi...

Page 11: ...igher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control OFF Cover pans 4 Allow solution to soak at least one hour or overnight...

Page 12: ...unit will not hold water Drain valve not fully closed Check drain valve for debris and close fully Drain valve damaged or pan s leaking Contact your Authorized Wells Service Agency for repairs Auto f...

Page 13: ...40V SINGLE THREE PHASE WIRING DIAGRAM FOR MOD 500TDM AND 527TDM WARMER W AUTO WATER FILL WATER PAN PROBE L3 L2 L1 4 3 2 1 PROBE COM 1 L3 L2 L1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 19 19 28 6 7 31 3 29...

Page 14: ...2 CLAMP 5 8 2C 46591 PANEL CNTROL P2 Z12288 2C 41974 2C 41974 P2 47863 P2 48178 LIGHT 2J 35687 LIGHT 2J 35687 GROMMET 2I 40034 CONTROL 2E 306865 KNOB 2R 40498 KNOB 2R 40498 BRKT P2 40843 CTRL 2T 45917...

Page 15: ...K 48198 2K 48197 2V 47650 2K 47662 2C 46591 make from 2H 36196 sold by the foot 2K 31040 WS 50131 2C 41974 WS 503713 2J 35687 2E 46529 2R 40498 2I 40034 2I Z12311 2T 45917 2K 34136X 2E 306865 2C 46591...

Page 16: ...PAN ASSY QTY 4 WS 500700 5P 21709 2V 47650 WS 503713 2K 47662 2K 48197 2K 48198 2C 46591 2I Z12311 2K 34136X 2R 40498 2K 31040 2E 306865 2I 40034 2E 46529 2C 46591 P2 46587 2J 35687 WS 50131 2C 41974...

Page 17: ...ENT PAN ASSY 2V 35609 PAN ASSY QTY 1 WS 504101 PAN ASSY QTY 4 WS 500700 5P 21709 2V 47650 WS 503713 2K 47662 2K 48197 2K 48198 2C 46591 2K 31040 2J 35687 WS 50131 2C 41974 2E 306865 2I 40034 2E 46529...

Page 18: ...rmer to hold one 7qt and one 4 qt DD 21618 Adapter top convert 12 x 20 warmer to hold four 2 qt insets 5D 21623 Adapter top convert 12 x 27 SMPT 27 to hold three 7 qt insets DD 21503 2 QT ROUND INSET...

Page 19: ...its approved for installation in wood counter tops One well units require one kit Two and three well units require two kits four and five well units require three kits DRAIN VALVE EXTENSION KIT extens...

Page 20: ...WELLS BLOOMFIELD LLC 10 Sunnen Dr St Louis MO 63143 telephone 314 678 6314 fax 314 781 2714 www wells mfg com...

Reviews: