background image

CUSTOMER SERVICE DATA

please have this information available if calling for service

RESTAURANT _____________________________  LOCATION  _____________ 

INSTALLATION DATE ________________________ TECHNICIAN ___________ 

SERVICE COMPANY ________________________________________________ 

 

ADDRESS ___________________________ STATE ______ ZIP__________ 

 

TELEPHONE NUMBER (_____)_____-_________ 

EQUIPMENT MODEL NO. _______________
EQUIPMENT SERIAL NO. _______________

VOLTAGE:(

check one

)              120          208       240  

 

DESCRIPTION  

 

 

 

 

PART NO.

ACCESSORIES
6 oz

. SOUP LADLE 

 

 

 

 

5J-21860

WELLSLOk EXTENSION kIT, for UL LISTED
      circular warmers only, adapt  to wood counter 

up to 1¾” thick 

 

 

 

 

5P-22592*

WELLSLOk EXTENSION kIT, for UL LISTED 
       12” x 20”  warmers only, adapt  to wood counter 

up to 1¾” thick 

 

 

 

 

5P-22593*

*  Wellslok Extension Kits for UL Listed units approved for

 

installation in wood counter tops 

One well units require one kit / Two and three well units require

 

two kits / four and five well units require three kits

DRAIN VALVE EXTENSION kIT, extension from
 

drain to counter front with remote handle, for use 

with “D” models only, excluding “DM” models   

5P-20385

DRAIN SCREEN 

 

 

 

 

5P-21709

OPTIONAL 72” WIRING, thermostatically controlled

     warmers 

 

 

 

 

 

**

**  contact factory customer service for availability

PARTS & SERVICE

17

IMPORTANT: Use only       

factory authorized service parts 

and replacement filters.

For factory authorized service, 

or to order factory  authorized 

replacement parts, contact 

your Wells authorized service 

agency, or call:
 

Wells Bloomfield, LLC

10 Sunnen Dr., P.O.Box  430129

St. Louis MO 63143 USA 

Service Dept.

phone: (888) 356-5362

fax:       (314) 781-2714

Service Parts Department 

can supply you with the name 

and telephone number of 

the WELLS  AUTHORIZED     

SERVICE AGENCY 

nearest you.

M01

1C.15 2M-308026 Owners Manual for Built-In Five-W

ell 

Auto-Fill Modual W

armers

M01

1C.15 2M-308026 Owners Manual for Built-In Five-W

ell 

Auto-Fill Modual W

armers

Summary of Contents for MOD-500TDMAF

Page 1: ...is appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if you have any...

Page 2: ...FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merchandise is unpacked notify the transportation company or carrier immediat...

Page 3: ...appliance will ensure that it gives you the very best performance and a long economical service life This manual contains the information needed to properly install this appliance and to use and care...

Page 4: ...osition is marked NOTE The dial position is an indication of the temperature setting Actual temperature will vary depending upon the type of product and food consistency B MOUNTING 1 Top mounted built...

Page 5: ...ns must be read and understood by all persons using or installing this appliance Cleanliness of this appliance is essential to good sanitation Read and follow all included cleaning instructions and sc...

Page 6: ...installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all accessories in a c...

Page 7: ...Code PLUMBING INSTALLATION For use in the State of Massachusetts this appliance must be installed in compliance with Massachusetts Fuel Gas and Plumbing Code CMR 248 1 IMPORTANT All plumbing installa...

Page 8: ...2 qt 4qt 7 qt and 11 qt sizes with lids and adapter tops b For dry operation a 6 deep pan or inset is recommended 2 Turn temperature control to HI or highest temperature setting 3 Allow warmer to pre...

Page 9: ...ells Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless steel however is mostly iron and will rust pit and corrode under the fol...

Page 10: ...nspect warmer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating element causing a potential fi...

Page 11: ...igher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control OFF Cover pans 4 Allow solution to soak at least one hour or overnight...

Page 12: ...unit will not hold water Drain valve not fully closed Check drain valve for debris and close fully Drain valve damaged or pan s leaking Contact your Authorized Wells Service Agency for repairs Auto f...

Page 13: ...40V SINGLE THREE PHASE WIRING DIAGRAM FOR MOD 500TDM AND 527TDM WARMER W AUTO WATER FILL WATER PAN PROBE L3 L2 L1 4 3 2 1 PROBE COM 1 L3 L2 L1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 19 19 28 6 7 31 3 29...

Page 14: ...2 CLAMP 5 8 2C 46591 PANEL CNTROL P2 Z12288 2C 41974 2C 41974 P2 47863 P2 48178 LIGHT 2J 35687 LIGHT 2J 35687 GROMMET 2I 40034 CONTROL 2E 306865 KNOB 2R 40498 KNOB 2R 40498 BRKT P2 40843 CTRL 2T 45917...

Page 15: ...K 48198 2K 48197 2V 47650 2K 47662 2C 46591 make from 2H 36196 sold by the foot 2K 31040 WS 50131 2C 41974 WS 503713 2J 35687 2E 46529 2R 40498 2I 40034 2I Z12311 2T 45917 2K 34136X 2E 306865 2C 46591...

Page 16: ...PAN ASSY QTY 4 WS 500700 5P 21709 2V 47650 WS 503713 2K 47662 2K 48197 2K 48198 2C 46591 2I Z12311 2K 34136X 2R 40498 2K 31040 2E 306865 2I 40034 2E 46529 2C 46591 P2 46587 2J 35687 WS 50131 2C 41974...

Page 17: ...ENT PAN ASSY 2V 35609 PAN ASSY QTY 1 WS 504101 PAN ASSY QTY 4 WS 500700 5P 21709 2V 47650 WS 503713 2K 47662 2K 48197 2K 48198 2C 46591 2K 31040 2J 35687 WS 50131 2C 41974 2E 306865 2I 40034 2E 46529...

Page 18: ...rmer to hold one 7qt and one 4 qt DD 21618 Adapter top convert 12 x 20 warmer to hold four 2 qt insets 5D 21623 Adapter top convert 12 x 27 SMPT 27 to hold three 7 qt insets DD 21503 2 QT ROUND INSET...

Page 19: ...its approved for installation in wood counter tops One well units require one kit Two and three well units require two kits four and five well units require three kits DRAIN VALVE EXTENSION KIT extens...

Page 20: ...WELLS BLOOMFIELD LLC 10 Sunnen Dr St Louis MO 63143 telephone 314 678 6314 fax 314 781 2714 www wells mfg com...