    3.  For “top-mounted”  warmers (i.e. warmers mounted from above  

 

the counter top):

 

a.  Verify that provided sealants are applied to the underside of the 

warmer top flange prior to setting the unit into the cutout.

 

b.  After installation, verify that the tabs on the Wellsloks are turned 

out to lock the warmer into the counter

 

c.  Apply a thin bead of food-grade silicone sealant around the  flange 

to seal it to the counter.

 

d.  Wellslok extension kits are available for installing warmers in 

counter tops  where the standard Wellslok would not normally 

reach.  The extension kit will adapt to counter tops up to 1¾” thick.

ELECTRICAL INSTALLATION

     1.  Refer to the product nameplate.  Verify the electrical service 

power.  Voltage and phase must match the nameplate 

specifications.  Wiring the warmer to the wrong voltage can 

severely damage the unit or cause noticeably decreased 

performance.  

     2.  Available electrical service amperage must meet or exceed the   

specifications listed on the specification sheet provided with the 

warmer.

     3.  Warmer and control unit must be connected to an appropriate 

building ground.  Ground connection will be marked “GND” or 

”       “ .

NOTE:  Wire gauge, insulation type and temperature rating , as  

well as type, size and construction of conduit, must meet or exceed   

applicable specifications of local codes and of the National         

Electrical Code.

PLUMBING INSTALLATION

For use in the State of Massachusetts, this appliance must be installed 

in compliance with 

Massachusetts Fuel Gas and Plumbing Code 

CMR 248.

     1.  IMPORTANT:  All plumbing installations must be performed by  

a qualified plumber.

     2.  AUTOFILL units are equipped with a DRAIN LINE:  Some 

jurisdictions may require an approved air gap or other 

 

back-flow  prevention device in the drain.  It is the responsibility  

of the plumber to determine such requirement, to provide and  

properly install the required device.

     3.  For  AUTOFILL units:  Some jurisdictions may require an approved 

back-flow preventer in the water supply line.  It is the responsibility 

of the plumber to determine such requirement,  

 

 

and to provide and properly install the required device.

 

 

Autofill supply must be connected to a COLD WATER line only.

 

NOTE:  Damage caused by 

leaks due to improper

installation is NOT covered by 

warranty. 

CAUTION:

SHOCk  HAzARD

The ground lug of this 

appliance must be connected 

to a suitable building ground.

IMPORTANT:

Contact a licensed electrician 

to install and connect electrical 

power to the appliance.

IMPORTANT:

Damage due to being 

connected to the wrong     

voltage or phase is NOT    

covered by warranty.

IMPORTANT:  Electrical      

installation other than as 

specified on the specification 

sheet will void the UL  listing, 

and may void the warranty. 
NOTE:  Plumb connections 

must be made in compliance 

with all Federal, State and  

Local Plumbing Codes and 

Ordinances.

M01

1C.15 2M-308026 Owners Manual for Built-In Five-W

ell 

Auto-Fill Modual W

armers

M01

1C.15 2M-308026 Owners Manual for Built-In Five-W

ell 

Auto-Fill Modual W

armers

Summary of Contents for MOD-500TDMAF

Page 1: ...is appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if you have any...

Page 2: ...FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merchandise is unpacked notify the transportation company or carrier immediat...

Page 3: ...appliance will ensure that it gives you the very best performance and a long economical service life This manual contains the information needed to properly install this appliance and to use and care...

Page 4: ...osition is marked NOTE The dial position is an indication of the temperature setting Actual temperature will vary depending upon the type of product and food consistency B MOUNTING 1 Top mounted built...

Page 5: ...ns must be read and understood by all persons using or installing this appliance Cleanliness of this appliance is essential to good sanitation Read and follow all included cleaning instructions and sc...

Page 6: ...installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all accessories in a c...

Page 7: ...Code PLUMBING INSTALLATION For use in the State of Massachusetts this appliance must be installed in compliance with Massachusetts Fuel Gas and Plumbing Code CMR 248 1 IMPORTANT All plumbing installa...

Page 8: ...2 qt 4qt 7 qt and 11 qt sizes with lids and adapter tops b For dry operation a 6 deep pan or inset is recommended 2 Turn temperature control to HI or highest temperature setting 3 Allow warmer to pre...

Page 9: ...ells Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless steel however is mostly iron and will rust pit and corrode under the fol...

Page 10: ...nspect warmer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating element causing a potential fi...

Page 11: ...igher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control OFF Cover pans 4 Allow solution to soak at least one hour or overnight...

Page 12: ...unit will not hold water Drain valve not fully closed Check drain valve for debris and close fully Drain valve damaged or pan s leaking Contact your Authorized Wells Service Agency for repairs Auto f...

Page 13: ...40V SINGLE THREE PHASE WIRING DIAGRAM FOR MOD 500TDM AND 527TDM WARMER W AUTO WATER FILL WATER PAN PROBE L3 L2 L1 4 3 2 1 PROBE COM 1 L3 L2 L1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 19 19 28 6 7 31 3 29...

Page 14: ...2 CLAMP 5 8 2C 46591 PANEL CNTROL P2 Z12288 2C 41974 2C 41974 P2 47863 P2 48178 LIGHT 2J 35687 LIGHT 2J 35687 GROMMET 2I 40034 CONTROL 2E 306865 KNOB 2R 40498 KNOB 2R 40498 BRKT P2 40843 CTRL 2T 45917...

Page 15: ...K 48198 2K 48197 2V 47650 2K 47662 2C 46591 make from 2H 36196 sold by the foot 2K 31040 WS 50131 2C 41974 WS 503713 2J 35687 2E 46529 2R 40498 2I 40034 2I Z12311 2T 45917 2K 34136X 2E 306865 2C 46591...

Page 16: ...PAN ASSY QTY 4 WS 500700 5P 21709 2V 47650 WS 503713 2K 47662 2K 48197 2K 48198 2C 46591 2I Z12311 2K 34136X 2R 40498 2K 31040 2E 306865 2I 40034 2E 46529 2C 46591 P2 46587 2J 35687 WS 50131 2C 41974...

Page 17: ...ENT PAN ASSY 2V 35609 PAN ASSY QTY 1 WS 504101 PAN ASSY QTY 4 WS 500700 5P 21709 2V 47650 WS 503713 2K 47662 2K 48197 2K 48198 2C 46591 2K 31040 2J 35687 WS 50131 2C 41974 2E 306865 2I 40034 2E 46529...

Page 18: ...rmer to hold one 7qt and one 4 qt DD 21618 Adapter top convert 12 x 20 warmer to hold four 2 qt insets 5D 21623 Adapter top convert 12 x 27 SMPT 27 to hold three 7 qt insets DD 21503 2 QT ROUND INSET...

Page 19: ...its approved for installation in wood counter tops One well units require one kit Two and three well units require two kits four and five well units require three kits DRAIN VALVE EXTENSION KIT extens...

Page 20: ...WELLS BLOOMFIELD LLC 10 Sunnen Dr St Louis MO 63143 telephone 314 678 6314 fax 314 781 2714 www wells mfg com...

Reviews: