background image

PRECAUTIONS AND GENERAL INFORMATION 

E6070 

AGENCY LISTING INFORMATION 

Refer to the 

product nameplate 

for the specific appliance for agency 

listings.  In general: 

This appliance conforms to NSF Standard 4 for sanitation only if    
installed in accordance with the supplied 

Installation Instructions. 

UL Listed warmers are 

U

 Listed under UL File E6070.

STD 4 

UL Listed Warmers 

WARNING: 

SHOCK HAZARD 

 

All servicing requiring access 
to non-insulated electrical 
components must be        
performed by a factory       
authorized technician. 
DO NOT open any access 
panel which requires the use 
of tools.  Failure to 
follow this warning can 
result in severe electrical 
shock.

 

CAUTION: 

RISK OF 
DAMAGE 

DO NOT connect or energize 
this appliance until all       
installation instructions are 
read and followed.  Damage 
to the appliance may result if 
these instructions are not 
followed. 

CAUTION: 

HOT SURFACE 

Exposed surfaces can be hot 
to the touch and may cause 
burns. 

This appliance is intended for use in commercial establishments 
only. 

This appliance is intended to hold pre-heated food for human      
consumption.  No other use is recommended or authorized by the 
manufacturer or its agents.

 

Operators of this appliance must be familiar with the appliance use, 
limitations and associated restrictions.  Operating instructions must be 
read and understood by all persons using or installing this appliance.

Cleanliness of this appliance is essential to good sanitation.  Read and 
follow all included cleaning instructions and schedules to ensure the 
safety of the food product. 

Disconnect this appliance from electrical power before performing any 
maintenance or servicing. 

This appliance is not jet stream approved.  Do not direct water jet or 
steam jet at this appliance, or at any control panel or wiring.  Do not 
splash or pour water on, in or over any controls,  control panel or     
wiring.    

Exposed surfaces of this appliance can be hot to the touch and may 
cause burns. 

Do not operate this appliance if the control panel is damaged.  Call 
your Authorized Wells Service Agent for service.

 

The technical content of this manual, including any wiring diagrams, 
schematics, parts breakdown illustrations and/or adjustment 
procedures, is intended for use by qualified technical personnel. 

Any procedure which requires the use of tools must be performed by a 
qualified technician. 

This manual is considered to be a permanent part of the appliance.  
This manual and all supplied instructions, diagrams, schematics, parts 
breakdown illustrations, notices and labels must remain with the 
appliance if it is sold or moved to another location. 

This appliance is made in the USA.  Unless otherwise noted, this 
appliance has American sizes on all hardware.

 

M

011C.11  2M

-308022 

  Owne

rs M

anual fo

r B

u

ilt

-In

 Single

-W

e

ll Au

to

-Fill M

odular 

W

a

rmer

Summary of Contents for MOD-100TDAF

Page 1: ...le for TRAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact yo...

Page 2: ...ult of normal use within the time period and limitations defined in this warranty will at Wells discretion have the parts replaced or repaired by Wells or a Wells authorized service agency THIS WARRAN...

Page 3: ...aintenance of this appliance will ensure that it gives you the very best performance and a long economical service life This manual contains the information needed to properly install this appliance a...

Page 4: ...stop at both ends The OFF position is marked NOTE The dial position is an indication of the temperature setting Actual temperature will vary depending upon the type of product and food consistency B...

Page 5: ...must be read and understood by all persons using or installing this appliance Cleanliness of this appliance is essential to good sanitation Read and follow all included cleaning instructions and sche...

Page 6: ...ore starting any installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all a...

Page 7: ...al Code E PLUMBING INSTALLATION For use in the State of Massachusetts this appliance must be installed in compliance with Massachusetts Fuel Gas and Plumbing Code CMR 248 1 IMPORTANT All plumbing inst...

Page 8: ...emperature control to HI or highest temperature setting 3 Allow warmer to preheat for approximately 30 minutes then set the control for the desired temperature Be sure to keep the warmer covered durin...

Page 9: ...lls Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless steel however is mostly iron and will rust pit and corrode under the foll...

Page 10: ...mer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating element causing a potential fire and or...

Page 11: ...her 3 Pour contents of one package of commercial delime cleaner in to each warmer pan Stir to dissolve cleaner Turn heat control OFF Cover pans 4 Allow solution to soak at least one hour or overnight...

Page 12: ...n valve not fully closed Check drain valve for debris and close fully Drain valve damaged or pan s leaking Contact your Authorized Wells Service Agency for repairs Auto fill unit overflows Water level...

Page 13: ...WIRING DIAGRAM 11 M011C 11 2M 308022 Owners Manual for Built In Single Well Auto Fill Modular Warmers...

Page 14: ...2K 34136 2K 34136 2E 46529 MOD100TDAF 6 2V 70774 metal body 100TDAF 6 208 primarily used on Chilis 2C 46591 2C 46591 P2 WL0080 120V P2 WL0071 208 240 P2 46587 OFF 0 L O H I WELLS WELLS 2 3 4 5 6 7 8...

Page 15: ...50 WS 503713 2T 45917 P2 40843 2J 35687 2R 40498 2K 31040 2K 47662 2K 48197 2K 48198 P2 306960 WS 50131 2E 306865 2C 41974 2I 40034 2I Z12311 2I Z12311 2K 34136X 2K 34136X 2E 46529 2C 46591 2C 46591 P...

Page 16: ...NOTES 14 M011C 11 2M 308022 Owners Manual for Built In Single Well Auto Fill Modular Warmers...

Page 17: ...NOTES 15 M011C 11 2M 308022 Owners Manual for Built In Single Well Auto Fill Modular Warmers...

Page 18: ...t 12 x 20 warmer to hold one 7qt and one 4 qt DD 21618 ADAPTER TOP convert 12 x 20 warmer to hold four 2 qt insets WS 21623 ADAPTER TOP convert 12 x 27 SMPT 27 to hold three 7 qt insets DD 21503 4 QT...

Page 19: ...units approved for installation in wood counter tops One well units require one kit Two and three well units require two kits four and five well units require three kits DRAIN VALVE EXTENSION KIT ext...

Page 20: ...WELLS MANUFACTURING 265 Hobson Street Smithville Tennessee 37166 telephone 888 356 5362 fax 314 781 2714 www wells mfg com...

Reviews: